Ramsey Oretronic IV Tramp Metal Detector REC 4479C
Page 61
Meters Per Speed Pulse
Base Address:
H1377
Type:
FLOAT32
Access:
Get/Set
Length:
1
Persistent:
Yes
Min
1E-6
Units
meters/pulse
Max
4E-2
This data item specifies the belt position change in meters corresponding to one speed pulse.
Actual Belt Speed
Base Address:
H1393
Type:
FLOAT32
Access:
Get Only
Length:
1
Persistent:
No
Min
N/A
Units
meters/sec
Max
N/A
This is the measured belt speed (product of the speed sensor rate and the meters per speed pulse).
Clip Fine Sensitivity
Base Address:
H1425
Type:
UINT16
Access:
Get/Set
Length:
N/A
Persistent:
Yes
Min
0
Units
Counts
Max
999
Default
250
This parameter specifies the fine sensitivity value to use in belt regions marked by a repair clip.
Clip Length
Base Address:
H1425
Type:
FLOAT
Access:
Get/Set
Length:
N/A
Persistent:
Yes
Min
0.3
Units
Meters
Max
9.144
Default
0.3
This parameter specifies the length of belt repair regions. After the upstream clip detector input goes active
the detector will be desensitized until either (a) the belt has moved the distance specified by this parameter or
(b) the downstream clip detector input goes active.
Clip Coarse Sensitivity Delta
Base Address:
H1457
Type:
INT16
Access:
Get/Set
Length:
N/A
Persistent:
No
Min:
-6
Max:
6
This is one of two parameters which specify the coarse sensitivity value to be used in clip regions. A clip region
is a region of the conveyor belt marked by a repair clip. In such regions the coarse sensitivity is the sum of this
register and the
register. This register is not persistent. This register is used during