Thermo Scientific Orion Versa Star VSTAR-PH Reference Manual Download Page 29

25

Thermo Scientific Orion 

V

ersa

 s

tar

 pH with LogR Temperature Module

CML #

Description

VSTAR92

Orion V

ersa

 s

tar

 pH/ISE/Conductivity/RDO/Dissolved Oxygen 

Benchtop Multiparameter Meter Kit

 

- Orion 

V

ersa

 s

tar

 meter 

- Orion 

V

ersa

 s

tar

 pH/ISE/temperature module 

- Orion 

V

ersa

 s

tar

 conductivity/temperature module 

- Orion 

V

ersa

 s

tar

 dissolved oxygen/temperature module 

- 8157BNUMD Orion ROSS Ultra Triode pH/ATC probe 

- 013005MD Orion DuraProbe conductivity cell, K=0.475 

- 083005MD Orion polarographic DO probe 

- 096019 Orion Star stirrer probe 

- 080017 calibration sleeve for DO probe 

- 080513 DO probe maintenance kit 

- 970802 BOD funnel/stirrer 

- 080360 BOD adapter 

- 810199 ROSS solution kit (475 mL each of pH 4, 7 and 10 buffers;  

  storage solution; cleaning solution; and pH electrode storage bottle) 

- 011007 conductivity standard, 1413 µS, 5x60 mL 

- Electrode arm with redesigned holder 

- Universal power adapter

VSTAR93

Orion V

ersa

 s

tar

 pH/ISE/Conductivity/RDO/Dissolved Oxygen 

Ultimate Benchtop Multiparameter Meter Kit

 

- Orion 

V

ersa

 s

tar

 meter 

- Two Orion 

V

ersa

 s

tar

 pH/ISE/temperature modules 

- Orion 

V

ersa

 s

tar

 conductivity/temperature module 

- Orion 

V

ersa

 s

tar

 dissolved oxygen/temperature module 

- 8157BNUMD Orion ROSS Ultra Triode pH/ATC probe 

- 013005MD Orion DuraProbe conductivity cell, K=0.475 

- 083005MD Orion polarographic DO probe 

- Two 096019 Orion Star stirrer probes 

- 080017 calibration sleeve for DO probe 

- 080513 DO probe maintenance kit 

- 970802 BOD funnel/stirrer 

- 080360 BOD adapter 

- 810199 ROSS solution kit (475 mL each of pH 4, 7 and 10 buffers;  

  storage solution; cleaning solution; and pH electrode storage bottle) 

- 011007 conductivity standard, 1413 µS, 5x60 mL 

- Two electrode arms with redesigned holders 

- Universal power adapter

Summary of Contents for Orion Versa Star VSTAR-PH

Page 1: ...Thermo Scientific Orion Versa Star pH with LogR Temperature Module Reference Guide...

Page 2: ...riode Minimum Stir Requirement MSR NISS Optimum Results Orion Dual Star Orion Star SAOB SMART AVERAGING SMART STABILITY Star LogR Star Navigator 21 Stat Face Triode are trademarks of Thermo Fisher Sci...

Page 3: ...libration 9 pH Calibration 9 RmV Calibration 9 ORP Calibration 10 Chapter 5 Temperature Calibration 11 LogR Temperature Calibration Information 11 LogR Calibration Technique 11 ATC Probe Calibration T...

Page 4: ...Appendix B About LogR Technology LogR Temperature Measurements 29 LogR Temperature Accuracy Tables 29 Appendix C Advanced Orion Versa Star Meter and pH with LogR Module s Electrode Diagnostics Electr...

Page 5: ...01 and 0 1 mV and RmV ranges from 2000 mV Automatic and manual datalogging options Up to 6 point pH calibration with automatic recognition for USA NIST and DIN buffers The ability to fix calibration...

Page 6: ...This page intentionally left blank...

Page 7: ...assign the probe to the channel in the setup menu for instrument settings 4 Set up work area with calibration buffers rinse water sample other supplies 5 Connect the meter for data collection Hyperter...

Page 8: ...dition and slope Calibration information with electrode slope from last calibration and buffer points The information on the display can be customized Enter the setup menu to make changes 1 Press Setu...

Page 9: ...Stability Smart Fast Medium Slow Averaging Off Automatic Smart Read Type AutoRead Timed Single Shot Continuous Alarm Limit CalDue Set Point Note Different modes mV RmV ORP in the pH module have setup...

Page 10: ...he meter will apply the same saving and exporting data conditions as with the set time interval to record and export data but lock after one timed reading has expired Press measure esc 1 to reset the...

Page 11: ...annel with LogR and press f3 Select 3 Press the right arrow key to highlight Temperature and press f3 Select 4 Use the arrow keys to highlight the desired Temperature Input The selection is automatica...

Page 12: ...8 Thermo Scientific Orion Versa Star pH with LogR Temperature Module This page intentionally left blank...

Page 13: ...setup menu and the meter allows custom buffers to be used for up to 6 calibration points Custom buffer option prompts for the nominal values and stores data 4 During calibration points can be edited o...

Page 14: ...MD and Orion 4M KCl filling solution cat no 900011 or 4M KCl gel in electrode with cat no 9179BNMD are used The raw mV reading of an electrode with the same conditions is 220 mV at 25 C One standard c...

Page 15: ...y For example for measurements around 20 C calibrate at 10 C and 30 C For a temperature span greater than 20 C a three point temperature calibration is recommended For many samples a single point cali...

Page 16: ...Done key must be pressed Press measure esc 1 key or f1 Back to exit calibration without saving ATC Probe Calibration Technique The ATC temperature display has a relative accuracy of 0 1 C ATC probes...

Page 17: ...key If the meter is in timed or continuous read modes the meter will immediately start taking readings 4 If in AutoRead mode and datalog is enabled default the reading will automatically be stored whe...

Page 18: ...14 Thermo Scientific Orion Versa Star pH with LogR Temperature Module This page intentionally left blank...

Page 19: ...he last calibration data stored for each method Use the channel setup to access and modify methods 1 Press f3 setup key 2 Use the arrow keys to highlight the appropriate channel Press f3 select 3 Use...

Page 20: ...16 Thermo Scientific Orion Versa Star pH with LogR Temperature Module This page intentionally left blank...

Page 21: ...ys to highlight Inst Settings Press setup 3 Use the down arrow key to highlight your desired communication output port a USB b RS232 c USB Printer enables communication through the micro USB port dire...

Page 22: ...of the last 10 calibrations for each parameter of the meter The information will match the information recorded for that calibration To review calibration information 1 Press log view 9 key 2 Press ri...

Page 23: ...roubleshooting Guide Assistance After troubleshooting all components of your measurement system contact Technical Support Within the United States call 1 800 225 1480 and outside the United States cal...

Page 24: ...A Equipment Class Measurement control and laboratory Orion Star A series meters are EMC Class A Conforms with the following directives and standards EN61326 1 2006 Electromagnetic Compatibility EMC Di...

Page 25: ...EH ORP Mode Yes Temperature Range 5 to 105 C 23 to 221 F Resolution 0 1 Relative Accuracy 0 1 Offset Calibration 1 point LogR Temperature Range 0 to 100 C 0 to 212 F Resolution 0 1 Relative Accuracy...

Page 26: ...meter Orion Versa Star conductivity temperature module Electrode arm with redesigned holder Universal power adapter VSTAR22 Orion Versa Star Conductivity Benchtop Meter Kit Orion Versa Star meter Orio...

Page 27: ...with Two pH ISE Modules Kit Orion Versa Star meter Two Orion Versa Star pH ISE temperature modules 8102BNUWP Orion ROSS Ultra pH electrode 096019 Orion Star stirrer probe 927007MD ATC probe stainless...

Page 28: ...trode storage bottle 810007 ROSS fill solution 5x60 mL Electrode arm with redesigned holder Universal power adapter VSTAR90 Orion Versa Star pH ISE Conductivity RDO Dissolved Oxygen Benchtop Multipara...

Page 29: ...electrode storage bottle 011007 conductivity standard 1413 S 5x60 mL Electrode arm with redesigned holder Universal power adapter VSTAR93 Orion Versa Star pH ISE Conductivity RDO Dissolved Oxygen Ult...

Page 30: ...body 927005MD Orion ATC probe epoxy body 013005MD Orion DuraProbe conductivity cell 4 cell K 0 475 013016MD Orion conductivity cell flow through K 0 1 083005MD Orion dissolved oxygen probe polarograp...

Page 31: ...n use is capable of performing automatic buffer recognition perform the following procedure 1 Set the measurement mode to mV Prepare the pH electrode according to the instructions in the pH electrode...

Page 32: ...int calibrations in the pH mode In this technique straight line segments are drawn between each successive pair of calibration points Separate slope and E0 values are calculated using the adjacent pai...

Page 33: ...logy makes this possible using most standard glass pH electrodes The system is based on using the electrical resistance of the glass sensing bulb as the temperature probe The logarithm of the resistan...

Page 34: ...N 0 29 0 06 0 003 0 001 9207BN 0 16 0 07 0 002 0 001 9256BN 0 27 0 07 0 003 0 001 9272BN 0 22 0 06 0 003 0 001 For 20 C temperature compensation spans Table 2 Three Point LogR Calibration Average Temp...

Page 35: ...maintenance will not be able to rejuvenate your electrode Viewing Electrode Resistance The pH electrode bulb resistance value can be found right on the measurement screen when LogR is selected for th...

Page 36: ...values in the table below While diagnostic testing at or near 25 C is ideal due to the resistance stability at this temperature this may not be possible Nonetheless it is important to maintain as many...

Page 37: ...the fill solution may be depleted Refer to the additional electrode care notes below for the proper fill solution levels of a refillable electrode If the resistance values show a super high resistanc...

Page 38: ...34 Thermo Scientific Orion Versa Star pH with LogR Temperature Module Notes...

Page 39: ...This page intentionally left blank...

Page 40: ...thermo com India Tel 91 22 4157 8800 wai asia thermofisher com Japan Tel 81 045 453 9175 wai asia thermofisher com China Tel 86 21 68654588 wai asia thermofisher com Singapore Tel 65 6778 6876 wai asi...

Reviews: