Safety, Warranty, and WEEE 

Warranty 

A-2

     AerosolSense Manual 

Thermo Scientific 

 

Seller warrants that the Products will operate or perform substantially in 

conformance with Seller's published specifications and be free from defects 

in material and workmanship, when subjected to normal, proper and 

intended usage by properly trained personnel, for the period of time set 

forth in the product documentation, published specifications or package 

inserts.  If a period of time is not specified in Seller’s product 

documentation, published specifications or package inserts, the warranty 

period shall be one (1) year from the date of shipment to Buyer for 

equipment and ninety (90) days for all other products (the "Warranty 

Period").  Seller agrees during the Warranty Period, to repair or replace, at 

Seller's option, defective Products so as to cause the same to operate in 

substantial conformance with said published specifications; provided that 

(a) Buyer shall promptly notify Seller in writing upon the discovery of any 

defect, which notice shall include the product model and serial number (if 

applicable) and details of the warranty claim; (b) after Seller’s review, Seller 

will provide Buyer with service data and/or a Return Material 

Authorization (“RMA”), which may include biohazard decontamination 

procedures and other product-specific handling instructions; and (c) then, 

if applicable, Buyer may return the defective Products to Seller with all 

costs prepaid by Buyer.  Replacement parts may be new or refurbished, at 

the election of Seller.  All replaced parts shall become the property of Seller.  

Shipment to Buyer of repaired or replacement Products shall be made in 

accordance with the Delivery provisions of the Seller’s Terms and 

Conditions of Sale.  Consumables, including but not limited to lamps, 

fuses, batteries, bulbs and other such expendable items, are expressly 

excluded from the warranty under this warranty.    
Notwithstanding the foregoing, Products supplied by Seller that are 

obtained by Seller from an original manufacturer or third party supplier are 

not warranted by Seller, but Seller agrees to assign to Buyer any warranty 

rights in such Product that Seller may have from the original manufacturer 

or third party supplier, to the extent such assignment is allowed by such 

original manufacturer or third party supplier.   
In no event shall Seller have any obligation to make repairs, replacements 

or corrections required, in whole or in part, as the result of (i) normal wear 

and tear, (ii) accident, disaster or event of force majeure, (iii) misuse, fault 

or negligence of or by Buyer, (iv) use of the Products in a manner for which 

they were not designed, (v) causes external to the Products such as, but not 

limited to, power failure or electrical power surges, (vi) improper storage 

and handling of the Products or (vii) use of the Products in combination 

with equipment or software not supplied by Seller.  If Seller determines 

that Products for which Buyer has requested warranty services are not 

covered by the warranty hereunder, Buyer shall pay or reimburse Seller for 

all costs of investigating and responding to such request at Seller's then 

Warranty 

Summary of Contents for AerosolSense 2900

Page 1: ...AerosolSense 2900 Sampler Manual In air pathogen surveillance solution Part Number 121561 00 18March2021...

Page 2: ......

Page 3: ...tridge 2 2 Removing the Sample Cartridge 2 5 Testing Services 2 7 Self Testing On site Lab 2 7 Third Party Testing Lab 2 7 Thermo Fisher Scientific Testing Services 2 7 Cleaning Instructions 2 8 Safet...

Page 4: ......

Page 5: ...ty safety protocols Confidently help protect employees and communities while maintaining business and operational continuity Figure 1 1 AerosolSense 2900 Sampler The AerosolSense Sampler has the follo...

Page 6: ...e cartridge is removed placed into a biohazard bag and sent to a laboratory for PCR testing There are three laboratory testing options 1 self testing at on site lab 2 third party lab testing or 3 Ther...

Page 7: ...Introduction Product Description Thermo Scientific AerosolSense Manual 1 3 Figure 1 3 AerosolSense Sampler Front View Figure 1 4 AerosolSense Sampler Inside View...

Page 8: ...Introduction Product Description 1 4 AerosolSense Manual Thermo Scientific Figure 1 5 AerosolSense Sampler Back View...

Page 9: ...le collection holder and media Single use sampling cartridge containing 2 1 inch collection substrates Safety and electrical designations TUV SUD CE UKCA ROHS Sample flow control 200 L per minute Oper...

Page 10: ......

Page 11: ...bstructed 2 Plug the power cord into an outlet with the appropriate voltage Equipment Damage The AerosolSense Sampler is supplied with a three wire grounding cord Under no circumstances should this gr...

Page 12: ...mple cartridge in the sampler 1 Open the front door of the sampler using the key 2 Unscrew the sample cartridge cap and screw it onto the tray for storage Figure 2 2 Unscrewing the Sample Cartridge Ca...

Page 13: ...clockwise to screw it on until it no longer turns 5 Make sure that the collection substrate is facing up Figure 2 4 Collection Substrate Facing Up 6 Fully push in the plunger The LED will flash green...

Page 14: ...AerosolSense Manual Thermo Scientific 7 Close the door and lock using the key The LED will be solid yellow to show the system is ready to sample Figure 2 6 Closing the Door 8 The LED will turn green...

Page 15: ...time has elapsed proceed to remove the sample cartridge The LED will remain green until the sampler door is opened When the door is opened the LED will turn red Note The key is needed to open the doo...

Page 16: ...4 Turn the cartridge counter clockwise until it comes out of the sample cartridge port Figure 2 10 Turning the Sample Cartridge Counter Clockwise 5 Screw on the cartridge cap Figure 2 11 Sample Cartri...

Page 17: ...arty testing lab Please advise your testing lab to follow the AerosolSense sample preparation procedure in order to support testing protocol To download the procedure visit the In Air Pathogen Surveil...

Page 18: ...Basic Operation Cleaning Instructions 2 8 AerosolSense Manual Thermo Scientific Perform periodic cleaning with an alcohol based wipe as appropriate based on the sampler usage Cleaning Instructions...

Page 19: ...ill result in death or serious personal injury if the warning is ignored A hazard is present or an unsafe practice can result in serious personal injury if the warning is ignored The hazard or unsafe...

Page 20: ...s may be new or refurbished at the election of Seller All replaced parts shall become the property of Seller Shipment to Buyer of repaired or replacement Products shall be made in accordance with the...

Page 21: ...PRIOR WRITTEN APPROVAL OR ANY USE OF REPLACEMENT PARTS NOT SUPPLIED BY SELLER SHALL IMMEDIATELY VOID AND CANCEL ALL WARRANTIES WITH RESPECT TO THE AFFECTED PRODUCTS THE OBLIGATIONS CREATED BY THIS WAR...

Page 22: ...mo Fisher Scientific s compliance with these Directives the recyclers in your country and information on Thermo Fisher Scientific products which may assist the detection of substances subject to the R...

Page 23: ...1 Figure 2 2 Unscrewing the Sample Cartridge Cap 2 2 Figure 2 3 Aligning the Cartridge 2 2 Figure 2 4 Collection Substrate Facing Up 2 3 Figure 2 5 Plunger In 2 3 Figure 2 6 Closing the Door 2 4 Figu...

Page 24: ......

Page 25: ......

Page 26: ...ermofisher com aerosolsense 2021 Thermo Fisher Scientific Inc All rights reserved All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified EPM_Aeroso...

Reviews: