background image

WEEE Compliance

WEEE Compliance

. This product is required to comply with the European Union’s Waste 

Electrical & Electronic Equipment (WEEE) Directive 2002/96EC. It is marked with the 

following  symbol.  Thermo  Fisher  Scientific  has  contracted  with  one  or  more 

recycling/disposal  companies  in  each  EU  Member  State,  and  this  product  should  be 

disposed of or recycled through them. Further information on our compliance with these 

Directives, the recyclers in your country, and information on Thermo Scientific products 

which may assist the detection of substances subject to the RoHS Directive are available at 

www.thermo.com/

Great Britain

WEEE  Konformittät

.  Dieses  Produkt  muss  die  EU  Waste  Electrical  &  Electronic 

Equipment  (WEEE)  Richtlinie  2002/96EC  erfüllen.  Das  Produkt  ist  durch  folgendes 

Symbol  gekennzeichnet.  Thermo  Fisher  Scientific  hat  Vereinbarungen  getroffen  mit 

Verwertungs-/Entsorgungsanlagen in allen EU-Mitgliederstaaten und dieses Produkt muss 

durch  diese  Firmen  widerverwetet  oder  entsorgt  werden.  Mehr  Informationen  über  die 

Einhaltung dieser Anweisungen durch Thermo Scientific, dieVerwerter und Hinweise die 

Ihnen nützlich sein können, die Thermo Fisher Scientific Produkte zu identizfizieren, die 

unter diese RoHS. Anweisungfallen, finden Sie unter www.thermo.com/

Deutschland

Conformità WEEE

.

 

Questo prodotto deve rispondere alla direttiva dell’ Unione Europea 

2002/96EC in merito ai Rifiuti degli Apparecchi Elettrici ed Elettronici (WEEE). 

È marcato col seguente simbolo.Thermo Fischer Scientific ha stipulato contratti con una o 

diverse società di riciclaggio/smaltimento in ognuno degli Stati Membri Europei. Questo 

prodotto  verrà  smaltito  o  riciclato  tramite  queste  medesime.  Ulteriori  informazioni  sulla 

conformità  di  Thermo  Fisher  Scientific  con  queste  Direttive,  l’elenco  delle  ditte  di 

riciclaggio  nel  Vostro  paese  e  informazioni  sui  prodotti  Thermo  Scientific  che  possono 

essere utili alla rilevazione di sostanze soggette alla Direttiva RoHS sono disponibili sul sito 

www.thermo.com/

Italia

Conformité WEEE

. Ce produit doit être conforme à la directive euro-péenne (2002/96EC) 

des  Déchets  d’Equipements  Electriques  et  Electroniques  (DEEE).  Il  est  marqué  par  le 

symbole suivant. Thermo Fisher Scientific s’est associé avec une ou plusieurs compagnies de 

recyclage dans chaque état membre de l’union européenne et ce produit devraitêtre collecté 

ou  recyclé  par  celles-ci.  Davantage  d’informations  sur  laconformité  de  Thermo  Fisher 

Scientific à ces directives, les recycleurs dans votre pays et les informations sur les produits 

Thermo Fisher Scientific qui peuvent aider le détection des substances sujettes à la directive 

RoHS sont disponibles sur www.thermo.com/

France

  

1

9

 

Summary of Contents for 18LCEETSA

Page 1: ...1 General Purpose Refrigerators and Freezers 326702H05 Rev B Model 18LCEETSA Installation and Operation Manual...

Page 2: ...on 6 Clearance 6 Electrical 7 Be Advised 7 Environmental Operating Conditions 12 Start Up Procedure 12 How to Save Energy 13 Safety Tips 13 Troubleshooting 14 Maintenance 15 Cleaning of Units 15 Inter...

Page 3: ...afety Alert Important operating instructions To reduce the risk of injury or poor performance of the unit read the user manual before putting the equipment into operation WARNING Indicates an immediat...

Page 4: ...ges Refrigerators 0 C to 8 C Freezers 6 C to 20 C Only Explosion Proof Units or Flammable Material Storage Units are to be used for the storage of flammable inventory samples These are not considered...

Page 5: ...performance features The need to add these features should be determined by your industrial hygienist or safety officer These units are not suitable for corrosive environments WARNING DO NOT store fla...

Page 6: ...for a damage inspection promptly Unpacking Use the list below when unpacking to verify that the complete unit has been received Do not discard packing materials until all is accounted for The followin...

Page 7: ...COMBUSTIBLE MATERIALS OR EXPLOSIVE GASES DO NOT USE IN THE PRESENCE OF PRESSURIZED OR SEALED CONTAINERS FIRE OR EXPLOSION MAY RESULT CAUSING DEATH CAUTION BEFORE CONNECTING THE FINAL POWER SUPPLY CHE...

Page 8: ...ATION To Install the Toe Grille 1 Attach toe grille support bracket to cabinet using 3 bolts supplied 2 Install left toe grille cover onto slot on left side of toe grille 3 Attach toe grille to cabine...

Page 9: ...top hinge cover Trace around the hinge with a soft lead pencil This makes reinstallation easier Remove top hinge and lift door off center hinge pin Set door aside 3 Unscrew center hinge pin using adju...

Page 10: ...two outside screws on opposite side of refrigerator remove inside screw and install center hinge 7 Remove three screws on bottom hinge and anti tip bracket if equipped with socket wrench 8 Install bot...

Page 11: ...t up on opposite side of door while tightening screws to install top hinge 17 There are two toe grille covers provided in your literature packet one for the right side and one for the left side Instal...

Page 12: ...of normal rated line 15 C to 32 C This product is intended for use indoors only Refer to IEC 664 1 Start Up Procedure Rotate the control knob clockwise to lower the temperature and counter clockwise t...

Page 13: ...ot humid weather Make certain that the door is closed tightly Set operating temperature no colder than necessary for the items being refrigerated Safety Tips After a unit is in operation do not touch...

Page 14: ...old air to escape This causes unit to work harder than necessary to maintain cold temperatures Re seat or replace the gasket if worn If you have temperature set too cold this may cause unit to run con...

Page 15: ...te especially when removing items from freezer units Do not use abrasive scouring powders waxes solvents furniture polish undiluted detergents or cleansers containing petroleum products on the surface...

Page 16: ...eplacement parts information and pricing please call the Customer Service Department at 800 438 4851 and have the unit s model serial and code numbers available This information is located on data pla...

Page 17: ...dealer from whom you purchased this unit or can be obtained promptly from the factory When service or replacement parts are needed we ask that you check first with your dealer If the dealer cannot han...

Page 18: ...representative ii misuse including use inconsistent with written operating instructions for the product mishandling contamination overheating modification or alteration of the product by any customer...

Page 19: ...fallen finden Sie unter www thermo com Deutschland Conformit WEEE Questo prodotto deve rispondere alla direttiva dell Unione Europea 2002 96EC in merito ai Rifiuti degli Apparecchi Elettrici ed Elettr...

Page 20: ...can be found on the dataplate attached to the equipment If available please provide the date purchased the source of purchase manufacturer or specific agent rep organization and purchase order number...

Page 21: ...Thermo Fisher Scientific Inc 275 Aiken Road Asheville NC 28804 United States www thermofisher com 326702H05 Rev B...

Reviews: