31
Cooling Speed Set-ups
OH6F*072DV4
Furnace Motor Current
Draw (Amps / Watts) vs.
External Static Pressure (in W.C)
Air Flow
Static Pressure (Amps/Watts)
Fan
Control
SW 1
Switch
Settings
Clg. Tonage
Cool
Continuous
0.2
0.5
6-OFF
5-OFF
4-OFF
2
799
500
1.2/109
2.1/186
6-OFF
5-OFF
4-ON
2.5
1017
508
1.8/160
2.5/230
6-OFF
5-ON
4-OFF
3
1210
605
2.4/220
3.3/308
6-OFF
5-ON
4-ON
3.5
1404
702
3.2/305
4.2/409
Factory
SW1
Switch
Settings
6-ON
5-OFF
4-OFF
4
1622
799
4.6/443
5.7/560
NOTE: All information is approximate. Results will vary by installation.
Figure 18-3: Cooling blower motor speed chart