Operating Instructions Premium HMI
6-22
Hourmeter Display
Press the NEXT or PREVIOUS key to scroll through the enabled hourmeters.
Scroll Through Hourmeters
Hourmeter names and definitions are shown in the table below in the order they appear. Only hourmeters enabled in the
Guarded Access Menu will be shown. To return to the Premium Display, press the EXIT key.
Hourmeter Names and Definitions
Total Hours
Total number of hours the unit has been turned on (protection hours).
Total Run Time Hours
Total number of hours the unit has run in both diesel and electric mode.
Engine Hours
Total number of hours the unit has run in diesel mode.
Electric Run Hours
Total number of hours the unit has run in electric mode.
Zone 1 Run Time Hours:
Total number of hours Zone 1 has run.
Zone 2 Run Time Hours:
Total number of hours Zone 2 has run.
Zone 3 Run Time Hours:
Total number of hours Zone 3 has run.
Total Run Reminder 1
User Programmable - The number of hours before a Total Unit Run Time Maintenance Reminder 1 occurs.
Total Run Reminder 2
User Programmable - The number of hours before a Total Unit Run Time Maintenance Reminder 2 occurs.
Controller Power On
Total hours the controller and HMI control panel have been turned on.
Pretrip Reminder
User Programmable - number of hours before a Pretrip Reminder occurs.
Engine Reminder 1
User Programmable - The number of hours before an Engine Run Time Maintenance Reminder 1 occurs.
Engine Reminder 2
User Programmable - The number of hours before an Engine Run Time Maintenance Reminder 2 occurs.
Electric Reminder 1
User Programmable - The number of hours before an Electric Run Time Maintenance Reminder 1 occurs.
Electric Reminder 2
User Programmable - The number of hours before an Electric Run Time Maintenance Reminder 2 occurs.
IMPORTANT: If a programmable hourmeter is not enabled or the view for that hourmeter is not turned on it will not appear in the display
sequence.
MODE
Various operating modes can be selected using the Mode menu. Not all modes may be available, depending on settings of
other programmable features. The following modes may be available.
SINGLE ZONE CONTROL – MULTI ZONE CONTROL (SPECTRUM)
If enabled in Guarded Access, Single Zone Control allow single temperature operation. If Single Zone Control operation is selected then all
zones will be forced on and will control to the same setpoint. All bulkheads should be down to create one large compartment. Multi Zone
Control allows separate control for each configured zone.
Turn CYCLE-SENTRY On or Off
CYCLE-SENTRY Mode can be turned On or Off. If CYCLE-SENTRY Mode is turned Off then unit will run in Continuous
mode.
Keypad Lockout
If enabled in Guarded Access, the keypad can be locked to prevent unauthorized use. If the keypad is locked only the ON and
OFF keys function. The keypad will remain locked even if the unit is turned Off and back on. If Keypad Lockout is active, press
and hold any soft key for 5 seconds to deactivate the feature.
Summary of Contents for T-1000R
Page 14: ...Safety Precautions 2 6 Warning Decals 2e24151g0 ...
Page 34: ...Maintenance Inspection Schedule 4 10 ...
Page 57: ...Unit Description 5 23 Purge Mode UT Series 1 3 4 5 2 ...
Page 67: ...Unit Description 5 33 Zone 1 Cool and Zone 2 Cool UT SPECTRUM Units ...
Page 69: ...Unit Description 5 35 Purge Mode UT SPECTRUM Units ...
Page 71: ...Unit Description 5 37 Zone 1 Cool and Zone 2 Heat UT SPECTRUM Units ...
Page 72: ...Unit Description 5 38 ...
Page 74: ...Diesel Electric Menu 6 28 Adjust Brightness 6 29 Time 6 30 ...
Page 120: ...Operating Instructions Standard HMI 7 18 ...
Page 152: ...Engine Maintenance 9 14 T Series Fuel and Oil System Components TK 376 ...
Page 154: ...Engine Maintenance 9 16 T Series Fuel and Oil System Components TK 270 ...
Page 156: ...Engine Maintenance 9 18 UT Series Fuel System Components AMA768 ...
Page 172: ...Engine Maintenance 9 34 T Series Engine Mounting Components for 2 Cylinder Engine ...
Page 184: ...Engine Maintenance 9 46 ...
Page 238: ...Refrigeration Maintenance 10 54 ...
Page 246: ...Clutch Maintenance 11 8 ...
Page 258: ...Structural Maintenance 12 12 ...
Page 264: ...Mechanical Diagnosis 13 6 ...
Page 265: ...14 Electric Standby Diagnosis ...
Page 268: ...Electric Standby Diagnosis 14 4 ...
Page 269: ...15 Refrigeration System Diagnosis ...
Page 272: ...Refrigeration System Diagnosis 15 4 ...
Page 280: ...Remote Evaporators 16 8 ...