Operating Instructions Premium HMI
6-20
The following alarm codes clear automatically.
• Alarm Code 64 Pretrip Reminder - Clears when a Pretrip Test is performed.
• Alarm Code 84 Restart Null - Clears when the unit is no longer in a restart null due to a Prevent Alarm.
• Alarm Code 85 Forced Unit Operation - Clears when the unit is no longer running in a forced mode due to a Prevent Alarm.
• Alarm Code 91 Check Electric Ready Input - Clears automatically when the unit starts running.
• Alarm Code 92 Sensor Grades Not Set - Clears when the sensor grade is changed from 5H.
If the Limited Alarm Restarts feature is enabled the following additional alarm codes may only be cleared from the Guarded
Access Menu. If this is the case, the CLEAR soft key will not appear if the alarms are displayed from the Main Menu or the
Maintenance Menu.
• Alarm Code 10 High Discharge Pressure
• Alarm Code 23 Cooling Cycle Fault
• Alarm Code 24 Heating Cycle Fault
• Alarm Code 32 Refrigeration Capacity Low
Displaying and Clearing Alarm Codes
Alarms are displayed and cleared using the Alarm Menu. From the Premium Display, press the MENU key. (Figure "Menu
The Language Menu or Alarms Menu will appear. If the Language Menu appears press the NEXT key to show the Alarm
Menu. When the Alarms Menu is shown press the SELECT key.
Select Key
The Alarm Display will appear. If no alarms are present NO ALARMS will be shown.
No Alarms
If alarms are present, the quantity of alarms (if more than one) and the most recent alarm code number will be shown. In the
example in Figure , there are two alarms present. The most recent is Alarm Code 5 (Figure ). It indicates a problem with the
coolant temperature sensor.
Alarm Code 6
After the alarm situation is resolved press the CLEAR key to clear the alarm. For additional information regarding the alarm
shown on the display, press the HELP key. To display the next alarm, press the NEXT key.
Next Key
If a serious condition occurs, the unit will be shut down to prevent damage to the unit or the load. If this occurs, the display
will show that the unit is shut down and display the alarm code that caused the shutdown. In the example, the unit is shut down
due to low oil level. For additional information regarding the alarm shown on the display, press the HELP key.
Help Key
Summary of Contents for T-1000R
Page 14: ...Safety Precautions 2 6 Warning Decals 2e24151g0 ...
Page 34: ...Maintenance Inspection Schedule 4 10 ...
Page 57: ...Unit Description 5 23 Purge Mode UT Series 1 3 4 5 2 ...
Page 67: ...Unit Description 5 33 Zone 1 Cool and Zone 2 Cool UT SPECTRUM Units ...
Page 69: ...Unit Description 5 35 Purge Mode UT SPECTRUM Units ...
Page 71: ...Unit Description 5 37 Zone 1 Cool and Zone 2 Heat UT SPECTRUM Units ...
Page 72: ...Unit Description 5 38 ...
Page 74: ...Diesel Electric Menu 6 28 Adjust Brightness 6 29 Time 6 30 ...
Page 120: ...Operating Instructions Standard HMI 7 18 ...
Page 152: ...Engine Maintenance 9 14 T Series Fuel and Oil System Components TK 376 ...
Page 154: ...Engine Maintenance 9 16 T Series Fuel and Oil System Components TK 270 ...
Page 156: ...Engine Maintenance 9 18 UT Series Fuel System Components AMA768 ...
Page 172: ...Engine Maintenance 9 34 T Series Engine Mounting Components for 2 Cylinder Engine ...
Page 184: ...Engine Maintenance 9 46 ...
Page 238: ...Refrigeration Maintenance 10 54 ...
Page 246: ...Clutch Maintenance 11 8 ...
Page 258: ...Structural Maintenance 12 12 ...
Page 264: ...Mechanical Diagnosis 13 6 ...
Page 265: ...14 Electric Standby Diagnosis ...
Page 268: ...Electric Standby Diagnosis 14 4 ...
Page 269: ...15 Refrigeration System Diagnosis ...
Page 272: ...Refrigeration System Diagnosis 15 4 ...
Page 280: ...Remote Evaporators 16 8 ...