background image

9LHZLQJ&OHDULQJ$ODUP&RGHV

RXUPHWHUV

&<&/(6(175<RU&RQWLQXRXV

(FRQRP\0RGH

'LHVHORU(OHFWULF2SHUDWLRQ

63(&758076

0XOWL7HPS

&RQWURO6\VWHP

2SHUDWLQJ*XLGH

+0,&RQWURO3DQHO)HDWXUHV

2. Alarms are displayed and cleared with the 

Alarm Menu. From the Standard Display press 
the MENU key.

1

2

Language or Alarm Menu will appear. If “LANGUAGE” 
appears, press the NEXT key to show Alarm Menu. 

4. Alarm display will appear. If no alarms are present, 

NO ALARMS will appear. If alarms are present, 
quantity of alarms and most recent alarm code will 
be shown. If the alarm pertains to a specific zone, 
that zone will be identified. 

3

4

1. If an alarm condition occurs, an alarm message 

appears in place of the mode indication.

3. Press the SELECT key.

5. After the alarm is resolved, press the CLEAR key 

to clear the alarm. For information on the alarm, 
press the HELP key. To display the next alarm, 
press the NEXT key. Press EXIT to return to the 
Standard Display.

5

If a serious condition occurs, the unit will shut down 
to prevent damage. The display will indicate unit 
shutdown and the alarm code which caused it. A 
complete list of alarm codes can be found in the 
unit Operators Manual or Maintenance Manual.

1. From the Standard Display, press the MENU key. 

The Language or Alarm Menu will appear. Press 
the NEXT key display the Hourmeter Menu.

2. Press the SELECT key to see Hourmeter Display.

1

2

3

3. Press the NEXT or PREVIOUS key to scroll 

through the hourmeters.

1. From the Standard Display, press the MENU key. 

The Language or Alarm Menu will appear. Press 
the NEXT key display the MODE Menu.

2. Press SELECT key to change mode between 

CYCLE SENTRY and Continuous. Display will 
confirm change in progress and resulting mode. 
Display then returns to Mode Menu.

1

2

CYCLE SENTRY mode causes unit to start and stop 
automatically to maintain compartment setpoint, keep 
engine warm and battery charged. Continuous mode 
starts and runs unit continuously to maintain setpoint 
and constant airflow. 

From the Standard Display, press the MENU key. 
The Language or Alarm Menu will appear. Press the
NEXT key as required to display Economy Mode.

1. Press the SELECT key to turn Economy Mode on.

1

2

Economy Mode can be used for loads that do not 
require critical temperature control. 

2. The display will confirm the change, show new 

mode for 10 seconds, then return to Mode Menu.

Economy Mode can be turned off by pressing the 
SELECT key again. 

1. If unit is turned on while connected to electric 

power, Electric Standby screen will be displayed 
for 10 seconds. Unit will run normally.

1

2

Factory-set default is for automatic changeover to 
Electric Mode when the unit is connected to electric
power. Unit will switch back to Diesel power if 
electric power fails or is disconnected. 

2. If unit is turned on in Electric Standby Mode and 

electric power is not available, prompt will be shown.
Switch to Diesel Mode by pressing YES key.

1

2

3

5

7

4

6

1. ON Key

2. OFF Key

3. Multi-Purpose “Soft” Keys

4. Manual Defrost Key

5. High Speed Lockout Key

6. Zone 1 Display

7. Zone 2 Display

TK 52145-1-PC (Rev. 1, 08/03)

CAUTION: This is a quick reference guide. 
Always refer to the operating manual for 
detailed instructions.

Reviews: