1. Press the ON Key. TK logo is shown briefly.

2. Startup screen appears. Unit prepares to operate.

3. Standard Display indicates unit is ready to run.

4

4. Press OFF key to stop unit operation. 

Screen will display OFF, then go blank.

1

Standard Display 
is the default 
when no other 
display function is 
selected. Shows box temperature and setpoint or 
OFF for all zones. Two zone operation shown 
here. Zone 1 is – 9.4 F with –10 F setpoint. Zone 2 
is 35.8 F with 35 F setpoint. Top of display shows 
unit is in CYCLE SENTRY mode. Two arrows 
indicate that both zones are cooling.

1. At the Standard Display, press the soft key to 

show the Zone Display for the desired zone.

1

2

2. Selected zone is displayed.

3. “Turn Zone (number) ON/OFF” identifies zone 

and indicates that zone may turned ON (if 
presently off) or OFF (if presently on).

3

1. At the Standard Display, press the soft key to 

show the Zone Display for the desired zone.

1

2

2. Turn Zone ON or OFF by pressing soft key. 

3. Display will briefly indicate change in progress.

3

4. Display will show new zone setting, then return to 

Standard Display after 30 seconds.

4

1. At the Standard Display, press the soft key to show

Zone Display for the desired zone (Zone 2 shown).

2. Press the “-” and/or “+” soft keys to display 

setpoint. YES and NO soft keys also appear.      “-
” and/or “+” soft keys are used to change setpoint 
(here to 40 F). 

4

1

2

3. When desired setpoint is reached, 

press YES soft

key within 10 seconds

 to confirm and load 

3

4. Display will briefly show “PROGRAMMING NEW 

SETPOINT”, then return to the Standard Display.

Diesel engine preheats and starts are automatic in 
Continuous and CYCLE SENTRY modes. The 
engine will preheat and start as necessary if the unit
is on. The start screen will be displayed. Preheat and
start will be delayed in CYCLE SENTRY if there is no
need for the unit to run.

Caution: The engine may start automatically
at any time the unit is turned on.

Defrost cycles are usually initiated based on time or 
demand. Manual defrost is available if the zone is on
and the coil temperature is less than 45 F (7 C). Only
one zone may be defrosted at a time.

1. Press the DEFROST key. The display will prompt

for the zone to defrost

2. Press the soft key to select the zone to defrost. 

Defrost of that zone will begin (Zone 1 shown here).

1

2

3

3. The display will briefly show “PROGRAMMING 

DEFROST” and then “ZONE ‘X’ DEFROST 
STARTED” where X = zone1 or 2. 

4. Display will return to Standard Display. The zone 

in defrost will show “DEF.” Bar indicator shows 
approximated time to complete defrost cycle.

If preprogrammed, high speed operation can be 
locked out. Press the key to enable or disable the 
feature. Display shows lockout programming in 
progress and then active or inactive status.