Refrigeration Service Operations
80
6. Support the compressor and remove the
compressor mounting bolts from the flywheel
housing. For a compressor with a 7-quart
sump use The Compressor Installation Tool
(P/N 204-1087) to support the compressor as
follows:
a. Identify the four machined feet on the base
of the compressor sump. The Compressor
Installation Tools bridge the lower frame
rails and support the compressor directly
under these feet.
b. Position the Compressor Installation Tools
by inserting them from the end of the
compressor and sliding them into place on
the lower frame rails. Alternatively,
position the Compressor Installation Tools
by inserting them on a diagonal from
below the compressor and twisting them
into position over the lower frame rails.
7. Lift the service valves out of the way.
8. Slide the compressor to the left until the
coupling pins are clear.
9. Remove the compressor from the front of the
unit. Keep the compressor ports covered to
prevent dust, dirt, etc., from falling into the
compressor.
NOTE: When the compressor is removed
from the unit, the oil level should be noted,
or the oil removed from the compressor
should be measured so that the same amount
of oil can be added before placing the
replacement compressor in the unit.
Installation
1. If installing a 7-quart sump compressor, place
the Compressor Installation Tools on the
lower frame rails to support the compressor.
2. Slide the compressor into the unit.
3. Place the compressor in position and install
the mounting bolts.
4. Install the service valves using new gaskets
soaked in compressor oil. Connect the HPCO
wires, the HPSW wires, and install the
compressor oil filter.
5. Pressurize the compressor and test for
refrigerant leaks.
6. If no leaks are found, evacuate the
compressor.
7. Back seat the suction and discharge service
valves.
8. Operate the unit at least 30 minutes and then
inspect the oil level in the compressor. Add or
remove oil if necessary.
9. Check the refrigerant charge and add
refrigerant if needed.
Compressor Coupling Removal
1. After the compressor has been removed from
the unit, use the appropriate Allen tool
provided with removal tool P/N 204-991 (see
Figure 53 on page 81) to loosen the center
bolt, which holds the coupling to the
compressor shaft.
2. Attach the tool to the coupling with the
provided socket head screws and spacers. Two
sets of spacers are provided with the tool, use
the short spacers with shallow compressor
mounting flanges and the longer set for deeper
flanges. The side with the countersunk holes
should be toward the coupling.
3. To prevent the tool and crankshaft from
rotating, use one of the compressor to engine
mounting screws to pin the tool to the flange.
If a nut is used to prevent the bolt from falling
out, the nut should not be tightened.
4. Use the appropriate Allen tool to loosen the
coupling mounting screw.
5. Once the center screw has been loosened,
back the head against the tool and it should
push the coupling off the crankshaft as you
continuing turning the center screw in a
counter-clockwise direction. Using this tool
will prevent the coupling from popping off
because the center bolt and flatwasher will
hold it in place.
Summary of Contents for Spectrum DE 30-2
Page 4: ...4...
Page 12: ...Safety Precautions 12...
Page 16: ...Specifications 16...
Page 31: ...Unit Description 31 1 Access Panels 2 Defrost Dampers Figure 12 Back View of Unit 1 2 AGA215...
Page 42: ...Operating Instructions 42...
Page 48: ...Electrical Maintenance 48...
Page 106: ...Structural Maintenance 106...
Page 110: ...Mechanical Diagnosis 110...
Page 114: ...Remote Evaporator Specifications 114...
Page 116: ...Remote Evaporator Maintenance Inspection Schedule 116...
Page 122: ...Remote Evaporator Electrical Maintenance 122...
Page 126: ...Remote Evaporator Refrigeration Service Operations 126...
Page 128: ...Remote Evaporator Structural Maintenance 128...
Page 130: ...Remote Evaporator System Diagnosis 130...
Page 134: ...Wiring and Schematic Diagrams Index 134...
Page 135: ...135 Schematic Diagram Page 1 of 2...
Page 136: ...136 Schematic Diagram Page 2 of 2...
Page 137: ...137 Wiring Diagram Page 1 of 4...
Page 138: ...138 Wiring Diagram Page 2 of 4...
Page 139: ...139 Wiring Diagram Page 3 of 4...
Page 140: ...140 Wiring Diagram Page 4 of 4...