Refrigeration Service Operations
81
Compressor Coupling Installation
In a tapered fit joint the entire twisting load
should be handled by the friction fit between the
two tapered parts. The key is only a backup and is
used to index the parts correctly. When a taper fit
is machined and assembled properly a key is not
needed. In fact, if the key is not installed correctly
it may be worse than no key at all! If the key does
not fit easily into the keyway, it will push the
tapered components apart and the reduced friction
could lead to slippage and premature failure.
The following procedure requires the key to be
fitted after the tapers are pulled together with
20 ft-lb (27 N•m) torque. This insures that the key
cannot hold the tapers apart when the final bolt
torque is applied.
Use the following procedure to install a
compressor coupling on the compressor
crankshaft.
1. Clean the compressor shaft taper and coupling
bore taper with a solvent that leaves no oily
residue (such as naphtha, lacquer thinner,
brake cleaner or the like).
2. Inspect both mating surfaces for burrs,
oxidation and other surface imperfections.
Dress with crocus cloth if necessary and
re-clean as required.
1.
Coupling
5.
10 mm Allen Tool (for large shaft compressor)
2.
Long Spacers (supplied with tool)
6.
5/16 Allen Tool (for small shaft compressors)
3.
Short Spacers (supplied with tool)
7.
Coupling Removal Tool (P/N 204-991)
4.
Socket Head Bolts (supplied with Tool)
8.
Engine Mounting Flange
Figure 53: Compressor Coupling Removal Tool
AGA1059
1
3
4
8
5
6
7
2
Summary of Contents for Spectrum DE 30-2
Page 4: ...4...
Page 12: ...Safety Precautions 12...
Page 16: ...Specifications 16...
Page 31: ...Unit Description 31 1 Access Panels 2 Defrost Dampers Figure 12 Back View of Unit 1 2 AGA215...
Page 42: ...Operating Instructions 42...
Page 48: ...Electrical Maintenance 48...
Page 106: ...Structural Maintenance 106...
Page 110: ...Mechanical Diagnosis 110...
Page 114: ...Remote Evaporator Specifications 114...
Page 116: ...Remote Evaporator Maintenance Inspection Schedule 116...
Page 122: ...Remote Evaporator Electrical Maintenance 122...
Page 126: ...Remote Evaporator Refrigeration Service Operations 126...
Page 128: ...Remote Evaporator Structural Maintenance 128...
Page 130: ...Remote Evaporator System Diagnosis 130...
Page 134: ...Wiring and Schematic Diagrams Index 134...
Page 135: ...135 Schematic Diagram Page 1 of 2...
Page 136: ...136 Schematic Diagram Page 2 of 2...
Page 137: ...137 Wiring Diagram Page 1 of 4...
Page 138: ...138 Wiring Diagram Page 2 of 4...
Page 139: ...139 Wiring Diagram Page 3 of 4...
Page 140: ...140 Wiring Diagram Page 4 of 4...