![Thermo King 098203 Maintenance Manual Download Page 62](http://html1.mh-extra.com/html/thermo-king/098203/098203_maintenance-manual_1104405062.webp)
Operating Instructions
60
4. Located J1 connector top left side of PM, disconnect J1 connector from PM. See Figure 28 on page
5. Plug unit in and turn CB ON. Observe the condenser fan rotation to be correct, air out of condenser
grille, CCW. If wrong turn CB OFF and unplug unit. Swap 2 of the CP wires and recheck for correct
fan rotation.
1.
J1 Connector Disconnect from PM
2.
CP Wires Connected to Output Side of Main CB
3.
CF Wires Connected at J11 and Input Side of Compressor Contactor
Figure 28: Rotation Check
1
2
3
Summary of Contents for 098203
Page 2: ......
Page 3: ...MAGNUM TK 60275 4 MM Rev 3 08 15 Copyright 2012 Ingersoll Rand EMEIA Printed in Ireland...
Page 193: ...Refrigeration Maintenance 191 Figure 163 Filter Drier...
Page 200: ...Refrigeration Maintenance 198 Figure 169 Receiver Tank Figure 170 Water Cooled Condenser Tank...
Page 257: ...255 Schematic Diagram RELEASED 19 Sep 2013...
Page 258: ...256 Wiring Diagram Page 1 of 2 RELEASED 19 Sep 2013...
Page 259: ...257 Wiring Diagram Page 2 of 2 RELEASED 19 Sep 2013...
Page 263: ......