19
Unit Description
General Description
The Spectrum SB is a multi-temperature
refrigeration system designed to control the
temperatures in two or three compartments
(zones). The system allows any compartment to
be set at any temperature.
In the Spectrum SB 30/50-2 unit the evaporator in
the host unit controls one compartment (Zone 1),
and a remote evaporator controls the other
compartment (Zone 2). The Spectrum SB 30/50-3
has a second remote evaporator, which controls a
third compartment (Zone 3).
Brief descriptions of the following components
and features are given below:
•
Host Unit (Zone 1)
•
Spectrum Remote Evaporators (Zone 2 and
Zone 3)
•
Thermo King TK 486 Engine
•
Thermo King X430L Compressor
•
Smart Reefer Multi-Temp µP-IV
Microprocessor
•
CYCLE-SENTRY
TM
Start-Stop Controls
•
DAS (Optional)
•
Remote Control Box (Optional).
Host Unit
The host unit contains the diesel engine, the
compressor, the condenser, an evaporator and the
control box. The Model 50 host unit also contains
an electric motor. The unit is equipped with a
Smart Reefer Multi-Temp µP-IV Microprocessor,
which controls the operation of the host unit and
any remote evaporators. Refrigeration lines and
wire harness connect the host unit to the remote
evaporators.
The host unit mounts on the front of the trailer
with the unit evaporator portion extending into
trailer.
Figure 1: Front View
Spectrum Remote Evaporators
A Spectrum Remote Evaporator is mounted on the
ceiling of each remote compartment to provide
temperature control for Zone 2 and Zone 3 (if
used). A Spectrum Remote Evaporator with two
fans is called an S-2. A Spectrum Remote
Evaporator with three fans is called an S-3. Two
remote evaporators can be mounted in the same
remote compartment to provide more capacity.
Figure 2: S-3 Spectrum Remote Evaporator
Thermo King TK 486 Engine
The unit uses a quiet running Thermo King
TK 486, 4-cylinder, water cooled, direct injection
diesel engine. The TK 486 displaces 2.09 liters
and is rated at 33.9 horsepower (25.3 kilowatts) at
2200 rpm.
AJA920
AJA984
Summary of Contents for 002008
Page 4: ...4 ...
Page 30: ...Unit Description 30 Figure 9 Front View AJA920 ...
Page 31: ...Unit Description 31 1 Access Panels 2 Defrost Damper Figure 10 Back View 1 2 ARA104 ...
Page 114: ...Mechanical Diagnosis 114 ...
Page 116: ...Electric Standby Diagnosis 116 ...
Page 120: ...Remote Evaporator Specifications 120 ...
Page 122: ...Remote Evaporator Maintenance Inspection Schedule 122 ...
Page 128: ...Remote Evaporator Electrical Maintenance 128 ...
Page 132: ...Remote Evaporator Refrigeration Service Operations 132 ...
Page 134: ...Remote Evaporator Structural Maintenance 134 ...
Page 136: ...Remote Evaporator System Diagnosis 136 ...
Page 140: ...Index 140 ...
Page 142: ......
Page 143: ...143 Model 30 Schematic Diagram Page 1 of 2 ...
Page 144: ...144 Model 30 Schematic Diagram Page 2 of 2 ...
Page 145: ...145 Model 30 Wiring Diagram Page 1 of 4 ...
Page 146: ...146 Model 30 Wiring Diagram Page 2 of 4 ...
Page 147: ...147 Model 30 Wiring Diagram Page 3 of 4 ...
Page 148: ...148 Model 30 Wiring Diagram Page 4 of 4 ...
Page 149: ...149 Model 50 Schematic Diagram Page 1 of 2 ...
Page 150: ...150 Model 50 Schematic Diagram Page 2 of 2 ...
Page 151: ...151 Model 50 Wiring Diagram Page 1 of 5 ...
Page 152: ...152 Model 50 Wiring Diagram Page 2 of 5 ...
Page 153: ...153 Model 50 Wiring Diagram Page 3 of 5 ...