Structural Maintenance
107
8. De-energize and energize the damper several
times to make sure that the damper operates
correctly and seals properly.
9. Make sure the damper blade rests on the round
stops when the damper is open. Adjust the
round stops if necessary.
10. Install the damper assembly in the evaporator.
Condenser and Evaporator Fan
Location
When mounting the condenser or evaporator fan
and hub assembly on the fanshaft, the blowers and
inlet orifices must be properly aligned for proper
air flow and to prevent damage to the blower.
Condenser Fan Blower
1. Loosen the condenser inlet ring (spinning) on
the condenser coil bulkhead.
2. Slide the blower towards the inlet ring until it
contacts the inlet ring. This centers the inlet
ring in the blower orifice.
3. Tighten the inlet ring securely.
4. Slide the blower away from the inlet ring.
5. Pass a gauge wire completely around the
blower orifice to check for uniform clearance.
6. Spin the blower by hand to check for blower
distortion.
7. Position the blower so the edge of the inlet
ring lines up with the alignment mark on the
blower.
8. Torque blower hub bolts to 18 ft-lb (24 N•m).
Evaporator Fan Blower
1. Loosen the inlet rings on the sides of the
blower housing.
2. Center the blower wheel in the blower housing
with equal overlap on both inlet rings. The
overlap on each ring should be approximately
0.15 in. (3.8 mm).
3. Tighten the hub bolts that hold the blower
wheel on the fanshaft.
4. Center the inlet rings in the blower orifices.
Tighten the inlet rings securely.
5. Check the radial clearance by passing a wire
completely around the circumference of the
inlet rings and the blower wheel.
6. Torque the blower hub bolts to 18 ft-lb
(24 N•m).
1.
Blower Wheel
3.
Alignment Mark
2.
Inlet Ring
4.
Edge of Inlet Ring
Figure 73: Condenser Blower Alignment
AEA749
1
2
3
4
1.
Check Clearance with a Wire
2.
Blower Housing Sides
3.
Inlet Rings
4.
Evaporator Blower
5.
Radial Clearance
6.
Equalize Blower Inlet Overlap
Figure 74: Evaporator Fan Location
AEA720
Summary of Contents for 002008
Page 4: ...4 ...
Page 30: ...Unit Description 30 Figure 9 Front View AJA920 ...
Page 31: ...Unit Description 31 1 Access Panels 2 Defrost Damper Figure 10 Back View 1 2 ARA104 ...
Page 114: ...Mechanical Diagnosis 114 ...
Page 116: ...Electric Standby Diagnosis 116 ...
Page 120: ...Remote Evaporator Specifications 120 ...
Page 122: ...Remote Evaporator Maintenance Inspection Schedule 122 ...
Page 128: ...Remote Evaporator Electrical Maintenance 128 ...
Page 132: ...Remote Evaporator Refrigeration Service Operations 132 ...
Page 134: ...Remote Evaporator Structural Maintenance 134 ...
Page 136: ...Remote Evaporator System Diagnosis 136 ...
Page 140: ...Index 140 ...
Page 142: ......
Page 143: ...143 Model 30 Schematic Diagram Page 1 of 2 ...
Page 144: ...144 Model 30 Schematic Diagram Page 2 of 2 ...
Page 145: ...145 Model 30 Wiring Diagram Page 1 of 4 ...
Page 146: ...146 Model 30 Wiring Diagram Page 2 of 4 ...
Page 147: ...147 Model 30 Wiring Diagram Page 3 of 4 ...
Page 148: ...148 Model 30 Wiring Diagram Page 4 of 4 ...
Page 149: ...149 Model 50 Schematic Diagram Page 1 of 2 ...
Page 150: ...150 Model 50 Schematic Diagram Page 2 of 2 ...
Page 151: ...151 Model 50 Wiring Diagram Page 1 of 5 ...
Page 152: ...152 Model 50 Wiring Diagram Page 2 of 5 ...
Page 153: ...153 Model 50 Wiring Diagram Page 3 of 5 ...