Description of how the machine works

Operating instructions | Description of how the machine works

Temperature control & safety devices

The appliance has a microprocessor-con-

trolled temperature regulator with a 

digital temperature sensor. The sensor is 

positioned on the air intake side. The use 

of a digital precision sensor means that 

no subsequent adjustment of the con-

troller is necessary during the appliance's 

service life.

The measuring interval is 1 measurement 

/ second.

The correct functioning of the control 

programme is continuously monitored 

by an integrated programme sequence 

monitoring system.

Failure or a fault associated with the tem-

perature control immediately leads to 

the heating system cutting out. The tem-

perature of the appliance is continuously 

monitored by an independent safety 

circuit. If the temperature of the appli-

ance on the air intake side is higher than 

80 °C, this leads to a safety shutdown. In 

addition, there is an electromechanical 

temperature safety switch on the output 

side of the unit, which also switches off 

the appliance if a certain temperature is 

exceeded.

The function of the built-in fan is con-

trolled by a monitoring circuit. Failure 

of the fan, a blockage or sluggishness 

due to foreign objects that have been 

sucked in or age-related wear and tear is 

detected and this leads to a safety shut-

down. If the appliance was switched off, 

it is prevented from being switched on 

again if there is a blockage or if failure 

of the fan occurs. The unit is designed in 

such a way that it cannot be switched on 

again automatically after a power failure 

or a safety shutdown.

The correct function of the fan monitor-

ing can be checked by the user at  

any time by pressing the test button  

(see page 15).

Maintenance, repair & cleaning

Operating instructions | Maintenance, repair, cleaning

Maintenance & repair

The electrical safety of the device should 

be checked annually by a qualified elec-

trician as part of the equipment test 

(DGUV V3). Please pay attention to any 

regional and national legal regulations 

that may differ.

The function of the fan monitoring 

should be checked at least monthly by 

pressing the test button for fan mon-

itoring. To carry out the test, start the 

appliance normally by pressing the 

start button. The heaters must not be 

switched on (power switch 4.5 kW and 

power switch 9.0 kW set to OFF).

Correct operation is given if the appli-

ance cuts out from normal operation by 

pressing the button in the direction of 

Test 1 as well as by pressing it in the di-

rection of Test 2. If no shutdown occurs, 

the appliance must not be operated any 

further.

Further maintenance and repair work 

may only be carried out by the manufac-

turer or by authorised service partners 

(see service).

Cleaning

Before starting cleaning work, the ap-

pliance must be disconnected from the 

power supply. The appliance can be 

cleaned from the outside with a slightly 

damp cloth. Contamination caused  

by dust can be removed with a vacuum 

cleaner.

Service

For information concerning service  

contract partners, please visit  

www.thermo-bug.com or contact  

the manufacturer directly.

Summary of Contents for basic 3.0

Page 1: ...Thermo bug basic 3 0 Operating instructions ...

Page 2: ...ta Safety notes Description of the machine Scope of application Commissioning Operating the machine Description of how the machine works Maintenance repair cleaning Copy of the declaration of conformity 04 05 06 07 08 10 11 12 13 14 15 Annex Operating instructions Thermo bug basic 3 0 ...

Page 3: ...attention to the symbol on the ap pliance Attention Ensure that there is an ad equate escape route so that you can leave the operating range of the ap pliance without any hindrance at any time Attention Ensure that another person monitors the user who is located within the operating range of the appliance and that this person can initiate rescue measures if necessary Pay attention to the occupatio...

Page 4: ...der to avoid overheat ing the appliance and the associated fire hazard the appliance must not be covered Please pay attention to the symbol on the appliance n Make sure that there are no media which are easily flammable in the room to be heated n Make sure that these operating in structions are always available with this appliance especially when you make this appliance available to other persons ...

Page 5: ...e side Fan Actual temperature display Target temperature display Information button Power switch 4 5 kW Test button for fan monitoring Power switch 9 0 kW Temperature adjustment button Set button Temperature adjustment button Start button Operating control lamp Stop button Operating instructions Description of the machine ...

Page 6: ...professionals with expertise in thermal pest control and by trained amateurs The user of this appliance must be able to understand these operating instruc tions especially the safety notes Scope of application Intended use Thermo bug 3 0 is only intended for thermal pest control in closed dry rooms in accordance with the instructions in this manual Any other usage beyond the scope of this is not i...

Page 7: ... display The current actual temperature is shown in the top line of the display After press ing the set button the upper line of the display shows Set and the lower line shows the set control temperature tar get temperature Control temperature target temperature The control temperature can be set be tween 30 C and 70 C in increments of 1 C In order to set the control temper ature target temperatur...

Page 8: ... again if there is a blockage or if failure of the fan occurs The unit is designed in such a way that it cannot be switched on again automatically after a power failure or a safety shutdown The correct function of the fan monitor ing can be checked by the user at any time by pressing the test button see page 15 Maintenance repair cleaning Operating instructions Maintenance repair cleaning Maintena...

Page 9: ...hermo bug de Thermo bug GmbH Felix Wankel Straße 17 88339 Bad Waldsee Tel 49 0 7524 401 17 27 Fax 49 0 7524 401 17 28 info thermo bug com Operating instructions for download at https thermo bug de en thermo bug ...

Reviews: