| Thermo-bug 2.0 basic 

Operating manual 0218

Preface

Thermo-bug® 2.0 basic

Before taking this high-temperature 

radiator into operation, please read 

this operation manual with care and 

familiarise yourself with the operating 

elements.

In particular the danger notes should be 

given increased attention.

We assume no liability for damage from

improper handling and application; the 

warranty claim lapses.

The practical

thermal exterminator for

analogue single 

operation

Thermo-bug® 2.0 basic

Thermo-bug® 2.0

basic

Operating Manual

Before delivery, the radiator has been 

reviewed and tested for function. 

Please check the devicefor possible 

transport damage after delivery.

Summary of Contents for 2.0 basic

Page 1: ...Operating Manual Thermo bug 2 0 ...

Page 2: ...s In particular the danger notes should be given increased attention We assume no liability for damage from improper handling and application the warranty claim lapses The practical thermal exterminator for analogue single operation Thermo bug 2 0 basic Thermo bug 2 0 basic Operating Manual Before delivery the radiator has been reviewed and tested for function Please check the devicefor possible t...

Page 3: ...Thermo bug 2 0 basic 3 Operating manual 0218 Contents 04 First steps 06 Display and target value settings 08 Product properties and misdiagnosis 10 Safety notes guarantees and general notes ...

Page 4: ...Thermo bug 2 0 basic First steps Main switch Power switch 4 5 KW Power switch 9 KW 3 3 Sockets for temperature sensor Display for temperature sensor 4 Thermo bug 2 0 basic Operating manual 0218 ...

Page 5: ...es must be pushed in sequence in the order to get full power The display 2 can be used to set the desired temperature and to read the current temperature The maximum temperature can be set via the display 2 as well see below The temperature sensor should be placed at a height of approx 1 m in open space not covered since the pre set ambient air temperature will not be achieved otherwise To deactiv...

Page 6: ...T ALM H C Indicator lamps SET Set value setting active OUT Output relay active ALM Alarm relay active H C Cooling function active H C Heating function active Quit button exit menu Function button for target value setting and parameterisation Arrows and parameterisation Operating manual 0218 ...

Page 7: ...n to confirm the setting Thermo bug 2 0 basic 7 Deactivation Important Switch off power switch and of the Thermo bug 2 0 basic and let the fan lag for at least 5 minutes without heating so that the device can cool off Do not simply pull the plug This would lead to a danger that the connection cables overheat Then switch off via the main switch and disconnect from the mains 3 3 Sek 0 0 0 Operating ...

Page 8: ... n Pluggable external temperature sensor with 4 m cable n Temperature display with adjustable temperature n 230 V socket for the Thermo bug airblower with a 4A fuse n High performance fan for high temperatures n Overheating protection with automatic resetting n Housing protection type IP54 n Easy handling from low dead weight 15 kg Operating manual 0218 ...

Page 9: ...vice overheated Main switch off input voltage too high Air supply blocked fan standing Temperature controller is not on or defective PCB fuse defective Imbalance bearing damage No temperature sensor inserted Remedy Attach plug insert again New fuse Let cool off by 15 C switch on Measure mains voltage Keep air supply free cool off Activate replace Replace fuse on the PCB Inform manufacturer Insert ...

Page 10: ...eplaced by a specialist Guarantee The guarantee period shall be 12 months after the date of purchase of the device Any repairs will be performed free of charge during this warranty period if the defective parts show faults during our inspection Repair will not extend the warranty period The following damage shall be excluded from warranty n Unintended us n Non observation of the instructions n Imp...

Page 11: ...ally n DIN EN 12100 1 Safety of machinery Basic terms general principles of design part 1 General terminology method n DIN EN 12100 2 Safety of machinery Basic terms general principles of design part 2 Technical leading principles and specifications n DIN EN 60204 1 Safety of machinery Electrical equipment of machinery part 1 General requirements n DIN EN ISO13849 Safety of machinery Safetyrelated...

Page 12: ...dsee Phone 49 0 7524 401 17 27 Fax 49 0 7524 401 17 28 info thermo bug com www thermo bug com Krempel Co Werbeagentur GmbH Fotos Fotostudio Jacobs Krempel Co Thermo bug ist eine eingetragene Marke der Thermo bug GmbH Thermo bug 2 0 basic Operating Manual ...