Installation:
1. The heater should be installed by a qualified
plumber. We recommend the use of a knee pad
when installing this product. Cut the opening in
the plinth to the size shown in the table. Use
method A or B.
Model
Width A Height
B*
KPH
1300/1500/1800/2100
462mm
97mm
* The overall height of the grille is 100mm. Use
care when cutting the opening.
A
A
B
B
2. Fit isolating valves (not supplied) to the
system flow and return pipes. Failure to fit
isolating valves may mean that the
product is not serviceable in the event of
failure. Remove and discard the two
protection bungs in the copper pipes and
connect the flexible hoses between
system pipework and heater. Open the
isolating valves and check for leaks.
N.B. either pipe may be used on flow or return.
3. Vent air through bleed screw if
necessary.
Flate heat
screw driver
Bleed Valve
I
O
II
4.
Isolate electrical supply and
connect the heater electric cable to
the fused spur (3A). Ensure the
fused spur is not directly above the
heater and is accessible after
installation is complete. Electrical
works should be carried out by a
qualified electrician, in compliance
with local regulations.
I
O
II
Fused Spur
Flow
Return