GENERAL

GENERAL SAFETY INFORMATION AND PRECAUTIONS

As soon as you open the packaging, check imme-
diately that the contents are all present and undam-
aged. Contact the reseller from whom you pur-
chased the solar collector if you notice any prob-
lems.

This solar collector must be used only for the proper 
purpose for which it is designed and made. The 
manufacturer declines all responsibility, contractual 
or other, for damage to property or injury to persons 
or animals caused by improper installation, adjust-
ment, maintenance or use.

The solar collector must be serviced every two 
years.

Work near uncovered and live electrical wires, with 
which it is possible to come into contact, is only 
permitted under the following conditions:

 

- Wires must be free from voltage for the entire dura-
tion of the work. 

 

- Parts remaining live must be covered or accidental 
contact prevented.

 

- The following minimum safety distances must be 
respected:

 

1 m for voltages of up to 1000 Volts

 

3 m for voltages from 1000 to 11000 Volts

 

4 m for voltages from 11000 to 22000 Volts

 

5 m for voltages from 22000 to 38000 Volts

 

over 5 m if the voltage is not known.

 

Contact with open, live electrical wires may lead to 
electrocution and may even be fatal.

Always wear safety goggles when drilling. Always 
wear safety shoes, cut-proof protective gloves and 
a safety helmet when performing installation work.

Before beginning installation work on roofs, install 
the necessary fall prevention and fall arrest devices 
and ensure that all applicable safety standards are 
applied.

 

Use only tools and materials that conform to the 
safety standards that are applicable in the place of 
work.

Only wear overalls that have a safety harness (with a 
suitable safety or fall-arrest belt, ropes or slings, fall 
dampers or dissipaters). In the absence of adequate 
fall prevention and security devices, failure to use a 
proper safety harness may lead to falls from great 
heights with serious or even fatal consequences.

The use of ladders leaned against walls can lead to 
serious falls if the ladder slips, slides of falls. When 
using ladders, always ensure that they are stable, 
and that suitable ladder stops are present. If pos-
sible secure the ladder with hooks. Make sure that 
there are no live electrical wires near the ladder.

Especially when installing the solar collector as part 
of a domestic hot water system, follow the orienta-
tion and angle of the roof to ensure that the collector 
blends in with the architecture of the building.

This instruction manual is an integral part of the solar 
collector. It must be kept safe and must ALWAYS 
accompany the solar collector, even if it is sold 
to another owner or transferred to another user or 
to another installation. If you damage or lose this 
manual, order a replacement immediately from your 
local Technical Assistance Centre.

Summary of Contents for TSOL 20 N BLU

Page 1: ...TSOL 20 N BLU INSTALLATION INSTRUCTIONS ...

Page 2: ...2 2 ENGLISH CONFORMITY RANGE MODEL CODE TSOL 20 N BLU 20005823 Kit of 7 collectors TSOL 20 N BLU 20005825 Solar collectors conform to EN 12975 standard and to Solar Keymark certification standard ...

Page 3: ...energy savings for many years to come You can keep your new solar collector in peak condition by having it serviced regularly by an authorised THERMITAL Technical Assistance Centre This instruction manual contains important instructions and precautions that must be observed to ensure the trouble free installation and efficient functioning of your solar collector Please accept our thanks and our co...

Page 4: ...t 9 Location of probes 10 FOR THE INSTALLER Unpacking the collector page11 Dimensions and weight 12 Handling the collector 12 Installation 13 Filling the circuit 14 Checks 15 The following symbols are used in this manual bCAUTION Indicates actions that require cau tion and adequate preparation aSTOP Identifies actions that your MUST NOT do This manual Code 20007790 Rev 0 10 08 is made up of 16 pag...

Page 5: ...ive gloves and a safety helmet when performing installation work bBefore beginning installation work on roofs install the necessary fall prevention and fall arrest devices and ensure that all applicable safety standards are applied Use only tools and materials that conform to the safety standards that are applicable in the place of work bOnly wear overalls that have a safety harness with a suitabl...

Page 6: ...ollectors are easy to install Provided they are properly installed they provide reliable long lasting and extremely efficient service DESCRIPTION OF THE SOLAR COLLECTOR IDENTIFICATION The solar collectors are identified by two plates bIf these plates or any other means of clearly identifying the product are defaced removed or lost proper installa tion and servicing may be rendered difficult Data p...

Page 7: ...or return Alternative collector outlet b The outlet and the return must be connected to opposite sides Collector probe socket Collector outlet Collector return Direction of flow of heat transfer liquid Collector Ø 22 mm 3 2 mm anti reflection glass ...

Page 8: ... kg 180 kg 280 kg At angle of 45 At angle of 20 At angle of 45 At angle of 20 40 kg 90 kg 150 kg 320 kg 470 kg 624 kg 345 kg 430 kg 525 kg Diameter of connection pipes for a specific flow rate of 30 lt m2h Total surface area m2 ca 5 ca 7 5 ca 12 5 Diameter of copper pipe mm 10 12 15 18 Diameter of steel pipe DN16 DN20 1 0 8 0 6 0 4 0 2 0 0 0 02 0 04 0 06 0 08 0 1 0 12 Tm m2 K W Efficiency curve Te...

Page 9: ...ugs 18 Heat transfer fluid recovery M Collector outlet R Collector return bConnect no more than 6 collectors in series bIf copper pipes are used joints must be hot brazed bWe recommend the use of stainless steel pipes specially made for solar collectors for the outlet return and probe pipes The probe cable should be of the shielded type bDo not use plastic or multistrate pipes Operating temperatur...

Page 10: ...sion vessel 12 Pump 13 Flow regulator 14 Flow meter 15 Vent cock 16 Manual bleed valve accessory 17 Storage heater bottom probe 18 Storage heater top probe 19 Plugs 20 Heat transfer fluid recovery M Collector outlet R Collector return The temperature sensor must be installed in the nearest socket to the collector outlet Make sure that the sensor makes good contact with the socket Materials sensor ...

Page 11: ...velope containing certificate of warranty and label with bar code B Packages of 7 collectors Pallet contents 7 collectors Documentation envelope containing certificate of warranty and label with bar code bTake care not to lose the flat seal strapped to the fittings of the solar collector bThe instruction manual is an integral part of the solar collector Once located read it thoroughly and keep it ...

Page 12: ...he solar collector slightly and grip it at the four points shown A to lift it Use a hoist or other suitable lifting equipment to hoist the solar collector on to the roof bWear suitable personal protective equipment and use suitable safety devices aDo not dispose of the packaging material into the environment where it can become a potential haz ard Dispose of the packaging material in compli ance w...

Page 13: ...n conformity to relevant standards Lagging and insulation must be protected against damage by the weather and birds and animals Angle of collectors General Solar collectors are designed to be installed at angles of between 15 minimum and 75 maximum Make sure that the bleed and vent valves of the collec GENERAL INSTRUCTIONS tors remain open while the collectors are being installed Take care to prot...

Page 14: ...C temperature range It is also non toxic biodegradable and biocompat ible bDo NOT part fill the circuit with pure glycol then add water later bDo not use automatic or manual filling systems bIf the water supply is highly chlorinated use dis tilled water to prepare the glycol water mix 3 FILLING 1 Open the non return valve A 2 Open the air vent at the highest point in the system see figure alongsid...

Page 15: ...it seal test Safety valve check Anti freeze checked to ___ C pH of heat transfer fluid ____ Collector circuit bled Flow rate of 30l h per m2 checked Non return valve functioning DESCRIPTION OK Solar collectors Visual check of collectors Collectors cleaned if necessary Visual check of collector fixing points Visual check of roof impermeability Visual check of insulation lagging ...

Page 16: ...ax 049 9323972 www thermital com email info thermital it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liable to modification without notice Cod 20007790 ...