TUBING LENGTH AND ELEVATION DIFFERENCE LIMITS
No additional charge of compressor oil is necessary.
AF ACS B
L Tot. = Total tubing length (L1 + L2 + L3...)
Ln =
Maximum tubing length of a single indoor unit (n=1,2,3...)
L =
Keep AF ACS B tubing as short as possible (MAX. 10/12m)
REQUIRED AMOUNT OF ADDITIONAL REFRIGERANT
For tubing 1/4 “ - 3/8” = 15g/m
For tubing 1/4 “ - 1/2” = 20g/m
For tubing AF ACS B (1/2”) = 20g/m
LIMIT OF ELEVATION DIFFERENCE - OUTDOOR UNIT/INDOOR UNIT: 10m (H1, H2, H3, H4, H5, H6)
LIMIT OF ELEVATION DIFFERENCE BETWEEN INDOOR UNITS: 5m (H)
1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Level
6. Sabre saw or key hole saw
7. Hacksaw
8. Core bits ø 5
1
9. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for
reburring)
16. Hex. key
Tools required for installation (not supplied)
REGULATION (EU) No. 517/2014 - F-GAS
The unit contains R410A, a fluorinated greenhouse gas
with a global warming potential (GWP) of 2087.50. Do not
release R410A into the atmosphere.
1.
REDUCTION 1/2F - 3/8M + PIPE UNION 3/8 (2pcs)
2.
REDUCTION 3/8F - 1/2M + PIPE UNION 1/2 (2pcs)
3.
COVER (11pcs)
4.
DRAIN TUBE
5.
ADHESIVE DAMPER (4pcs)
6.
TUBES 1/4 - 3/8 + 1/2 - 5/8 for HK (1set)
ACCESSORIES SUPPLIED WITH THE UNIT
2
4
1
3
AT SHIPMENT
ADDITIONAL REFRIGERANT
MINIMUM LENGTH
L Tot. (m)
L n (m)
L Tot. (m)
L n (m)
L n (m)
AFEX140
MONO SPLIT
40
-
50
-
5
DUAL SPLIT
40
30
100
30
5
TRIAL SPLIT
40
30
100
30
5
QUADRI SPLIT
40
30
100
30
5
PENTA SPLIT
40
30
100
30
5
5
6
15
ENGLISH
Summary of Contents for 20112931
Page 1: ...AFEX MANUALE D INSTALLAZIONE IT INSTALLATION INSTRUCTIONS EN Unit esterna Outdoor unit AFEX140...
Page 42: ...ELECTRICAL WIRING DIAGRAM SCHEMA ELETTRICO 42 ENGLISH ITALIANO...
Page 44: ...REFRIGERANT CIRCUIT CIRCUITO FROGORIFERO 44 ENGLISH ITALIANO...
Page 45: ......
Page 46: ...46...
Page 47: ...47...