Thermionic Culture The Phoenix Operating Manual Download Page 7

channel 2. Channel 2 controls channel 1 when link is 
in. 
 

 
 
2.8 Pre-sets 
 

There are four pre-sets on the compressor chassis. 
The two just behind the front panel controls are to 
adjust for minimum low frequency distortion. They are 
set up with an oscilloscope for minimum distortion and 
phase shift at 40Hz. These pre-sets should not be 
adjusted, unless the valves are changed. 
 
The two pre-sets behind the meters are used to adjust 
the zero points of the meters. They can be adjusted 
with a long thin screwdriver, without removing the top 
cover of the compressor. Zero readings will vary a little 
with mains voltage and valve ageing. The zero setting 
is not critical, but both must be the same if 
compressing a stereo track. 
 
 

2.9 Meters 

 
The Phoenix can operate much faster than the meters 
will read. 
 
The meter scales should be used as a guide. Actual 
compression will vary slightly with individual valves 
and the meters may not be accurate at high readings. 
 

©

Thermionic Culture Ltd, January 1999 

6

 

Summary of Contents for The Phoenix

Page 1: ...CULTURE THERMIONIC T P HE HOENIX valve compressor OPERATING MANUAL...

Page 2: ...from the mains supply before any of the covers are removed Please also note that the power supply capacitors within this unit can remain charged even after the mains supply has been disconnected It is...

Page 3: ...tion 4 2 1 Output trim 4 2 2 Gain 4 2 3 Attack 4 2 4 Release 4 2 5 Threshold 5 2 6 Bypass 5 2 7 Link 5 2 8 Pre sets 6 2 9 Meters 6 3 Servicing Maintenance 7 3 1 Valves 7 3 2 Operating voltage Fuses 7...

Page 4: ...as a pair of mono compressors It has a soft knee or variable mu characteristic in that the compression ratio increases with the amount of compression being used Initial compression is 1 2 1 increasin...

Page 5: ...The attack control varies the rate at which the compressor starts to react Attack rates of between 4ms fully anti clockwise and 120ms fully clockwise can be achieved This control is typically set to...

Page 6: ...nk Links the two compressors for compressing a stereo track All controls are still in use so both channels should be set to around the same setting Ideally a 1kHz tone should be used to setup the leve...

Page 7: ...nd the meters are used to adjust the zero points of the meters They can be adjusted with a long thin screwdriver without removing the top cover of the compressor Zero readings will vary a little with...

Page 8: ...n be obtained in matched pairs from Thermionic Culture Ltd 3 2 Operating voltage Fuses The Phoenix Valve Compressor is factory set to operate from a 230V 50 60Hz AC mains supply It can be set to opera...

Page 9: ...time 0 004s to 0 12s Release time 0 06s to 2 2s Output impedance 600 Distortion will increase with compression typically 0 2 0 25 at 1kHz 100Hz with 8dB compression VALVE COMPLEMENT 2 ea Input Compres...

Page 10: ...Thermionic Culture Ltd 83 Collins Meadow Harlow Essex CM19 4EL UK Tel 44 0 1279 414770 Fax 44 0 1279 412233 Thermionic Culture Ltd January 1999 Printed in UK...