2.2.6
WT-C 1000 FC (6 bar)
Connections
1900
1570
1875
1222
1120
770
525
400
270
290
0
2
4
5
6
8
3
1325
1435
1540
870
970
1
Ø
850
Ø
1050
7
1 Venting (DN32)
2 Heat source (DN50, x4)
3 Tap water coil (4x12m, Ø22mm)
4 Temperature sensor (DN20, x2)
5 Heat source (DN32)
6 Heat source/Immersion heater (DN50)
7 Preheat coil/Tap water (4x12m, Ø22mm)
8 Drain tap/Temperature sensor (DN20)
Technical data
Total volume
907 litres
Storage volume V
885 litres
Total coil volume
22 litres
Coil surface (per coil)
3 m
2
Working pressure
6 bar
Test pressure
8,6 bar
Max. pressure, coil
10 bar
Max. temperature
100 °C
Max. immersion heater length
910 mm
Weight
262 kg
Standing loss S
135 W
Energy efficiency class
C
Dimensions (mm)
Ø22(x16)
90
100
Height
1900
Diameter
Ø1050
Diameter without insulation
Ø850
Depth, including coil connections
1149
Required ceiling height for tilting: 2090 mm
Installation Guide
WT-C Accumulator tanks
VIBND502
Thermia AB
14