Parameter
Meaning
IMM. HEAT 2
Operating time for IMMERSION HEATER 2.
IMM. HEAT 3
Operating time for IMMERSION HEATER 3.
EXT.AUX.HEAT
Operating time for external auxiliary heater.
7.11
DEFROST
Parameter
Meaning
DEFROSTS
Total number of defrosts carried out.
BETW. 2 DEFR
The operating time of the compressor in minutes between the two last defrosts.
TIME LAST DEFR
The operating time of the compressor in minutes since last defrost.
7.12
CALENDAR
Parameter
Meaning
CLOCK
Indicate day's date and time. Used in the calendar function and in the log at the alarm.
DATE: day-month-year, example: 01-jan-2011
CLOCK: hours:minutes, example: 20:30
HOT WATER BLOCK To block hot water production. Up to eight calendar settings can be defined.
Under CALENDAR SETTING, first select the menu TIME FUNCTION if blocking should be over a continuous time
period (DATE) or be recurring (DAYS / WEEK).
Then start and stop times are selected in the TIME SETTING menu.
EVU
EVU stops the heat pump and is a function that is used in certain countries to control electrical consumption. Up
to eight calendar settings can be defined
Under CALENDAR SETTING, first select the menu TIME FUNCTION if stop should be over a continuous time peri-
od (DATE) or be recurring (DAYS / WEEK).
Then start and stop times are selected in the TIME SETTING menu.
SILENT MODE
Function where the noise level of the heat pump fan is reduced. Up to eight calendar settings can be defined.
Under CALENDAR SETTING first select the menu TIME FUNCTION if reduction should be over a continuous time
period (DATE) or be recurring (DAYS / WEEK).
Then start and stop times are selected in the TIME SETTING menu.
TEMP. REDUCTION Function for reduction of temperatures. The new setpoints are those values that are stated for heat curve, shunt
groups and buffer tank in the information menu. Up to eight calendar settings can be defined.
Under CALENDAR SETTING first select the menu TIME FUNCTION if reduction should be over a continuous time
period (DATE) or be recurring (DAYS / WEEK).
Then start and stop times are selected in the TIME SETTING menu.
CONCRETE PROG.
See description in the section Concrete drying.
7.13
ALARM
Parameter
Meaning
NAME ALARM
Displays information about up to 10 alarms and alarm times.
NAME: Name of the alarm, example: AUX. HEATER
TIME: hours:minutes, example 20:45
DATE: day-month-year, example 13-jan-11