3
Connection to the water supply
Blue = cold water entry side (for filling)
Red = hot water exit side (hot water demand)
The Thermex Trend 4500 and 6000 devices are designed for use normal pressure systems. This
system allows water to be drawn from multi point use.
The connection pipes must be installed as shown in the drawing.
The water supply pipe and water discharge pipe are marked (red for hot water, blue for cold wa-
ter).
Connection to the electricity supply
The device must be filled with water. Only then may the appliance be connected to the electricity
supply.
Connection of the device to the power supply network must take place in accordance with the
NEC, IEC and as specified by local laws and regulations.
Avoid danger from damaged power supply cables. In the event of a damaged power supply cable,
the unit should be unplugged and the cable replaced by a licenced electrician immediately.
Ensure that the addition of this boiler will not overload the fuse protection in your electrical panel.
Internal modifications to the product may cause problems if this work is not carried out by author-
ized and qualified technical persons. The warranty only applies if the product has not been modi-
fied in any way, i.e. subject to it being in unchanged condition.
In order to avoid creating an unsafe situation by inappropriate resetting of the maximum tempera-
ture safety device, this unit may not be powered via an external switching device (a time switch for
example) or connected to a circuit, which is regularly switched on and off.
Detachment of the assembly panel