6
10 – hot water main, 11 –cold water shut-off valve, 12 – hot water shut-off valve, 13 –
protective cover, 14 –exhaust pipe of the safety valve, 15 – handle for opening pres-
sure relief valve, 16 – control panel, 17 – discharge pipe.
After connecting EWH make sure that cold water shut-off valve is open and hot
water shut-off valve (8) is closed. Open cold water tap in EWH (11), hot water outlet
valve (12) and hot water tap on mixer to ensure outflow of air from the EWH. When
the final EWH filling, water will continuously flow out of mixer tap. When connecting
EWH in places not provided with water supply it is permitted to supply water in EWH
from auxiliary tank using pumping station, or from reservoir placed at a height of not
less than 5 meters over the top of EWH.
Note:
for ease of maintenance during EWH operation it is recommended to install
drain valve (Fig. 1, p.4) in accordance with Fig. 1 (for models not equipped with
drainage pipe. (not in the scope of EWH supply)).
If the water pressure exceeds 0.7 MPa, at EWH cold water inlet, before the safety
valve (in the direction of water flow), the appropriate pressure reducing valve (not
supplied with the EWH) shall be installed to reduce water pressure to standard.
8.
CONNECTION TO POWER SUPPLY
Prior to the water heater connection to electrical network, make sure its parame-
ters complies with the technical specifications of the water heater.
ATTENTION! Prior to power activation make sure EWH is filled with water!
Water heater shall be earthed to ensure safe operation. EWH is equipped with the
stationary power cable (option) with Europlug (option). Power outlet shall have an
earth terminal with the connected earthing wire and located in the area protected from
moisture, or comply with the requirements not less than 1
РХ
4.
Electrical connections diagram