10 – hot water main, 11 –cold water shut-off valve, 12 – hot water shut-off valve, 13 – 
protective cover, 14 –exhaust pipe of the safety valve, 15 – handle for opening pres-
sure relief valve, 16 – control panel, 17 – discharge pipe. 

After connecting EWH  make  sure that cold  water shut-off valve is open and hot 

water shut-off valve (8) is closed. Open cold water tap in EWH (11), hot water outlet 
valve (12) and hot water tap on mixer to ensure outflow of air from the EWH. When 
the final EWH filling, water will continuously flow out of mixer tap. When connecting 
EWH in places not provided with water supply it is permitted to supply water in EWH 
from auxiliary tank using pumping station, or from reservoir placed at a height of not 
less than 5 meters over the top of EWH.  

Note:

 for ease of maintenance during EWH operation it is recommended to install 

drain  valve  (Fig.  1,  p.4)  in  accordance  with  Fig.  1  (for  models  not  equipped  with 
drainage pipe. (not in the scope of EWH supply)). 

If the water pressure exceeds 0.7 MPa, at EWH cold water inlet, before the safety 

valve  (in  the  direction  of  water  flow),  the  appropriate  pressure  reducing  valve  (not 
supplied with the EWH) shall be installed to reduce water pressure to standard.  

8.

 

CONNECTION TO POWER SUPPLY   

Prior to the  water heater connection to electrical network, make  sure its parame-

ters complies with the technical specifications of the water heater.

 

   

ATTENTION! Prior to power activation make sure EWH is filled with water! 

Water heater shall be earthed to ensure safe operation. EWH is equipped with the 

stationary  power  cable  (option)  with  Europlug  (option).  Power  outlet  shall  have  an 
earth terminal with the connected earthing wire and located in the area protected from 
moisture, or comply with the requirements not less than 1

РХ

4. 

Electrical connections diagram  

 

 

 

Summary of Contents for IF 100 H (pro)

Page 1: ...gned to provide with hot water for domestic and industrial facilities having a cold water supply line pressure of not less than 0 05 MPa and not more than 0 7 MPa EWH shall be operated indoors in heat...

Page 2: ...the inner tank Figure 1 p 17 The control panel in all models is on the front side of the EWH Figure 1 p 16 Tubular heating element THE thermostat and thermal switch sensors are mounted on the removabl...

Page 3: ...with pressure exceeding 0 7 MPa To connect EWH to the water supply without safety valve To drain water from EWH with power switched on To use spare parts not recommended by the manufacturer To use wat...

Page 4: ...at least 30 cm for all mod els In order to avoid damage of the user s and or third parties property in the event of a faulty hot water system it is required to install EWH in spaces with waterproofing...

Page 5: ...recommended to supply water to EWH through filter installed on the cold water main not included in the scope of supply Do not use used flexible feed pipes Do not operate the EWH without safety valve...

Page 6: ...operation it is recommended to install drain valve Fig 1 p 4 in accordance with Fig 1 for models not equipped with drainage pipe not in the scope of EWH supply If the water pressure exceeds 0 7 MPa a...

Page 7: ...2 p 5 on the control panel Mode 2 kW is accompanied by the indication of a control lamp Turbo Figure 2 p 9 1 3 kW is accompanied by the indication of a control lamp Optimal Figure 2 p 8 and 0 7 kW is...

Page 8: ...upply inlet or discharge valve a rubber hose sending the other end down the drain Open hot water tap on mixer and drain water from the EWH through the hose Remove the protective cover disconnect wires...

Page 9: ...water No backlights of indicator lamps 1 no voltage in electric network 2 damaged power cord 3 Thermal switch ac tuated and not switched on 1 Check voltage at the electrical outlet 2 Contact a qualif...

Page 10: ...erated When disposing of the EWH comply with local environmental laws and guidelines The manufacturer reserves the right to make changes to the design and specifications of the heater without prior no...

Page 11: ...nection The manufacturer shall not be liable for defects due to violations of principles of in stallation operation and maintenance of EWH set forth herein including in cases where these defects have...

Reviews: