M 530265000212022021
THERMEX
AIRGRIP
41
ADJUSTMENT OF THE VALVE
The valve’s settings for basic ventilation and forced ventilation shall be set in accordance with the sizing diagrams on page 11. The adjustment of the
valve is done using the buttons on the control panel.
1.
On/off light
2.
Timer function 20 min.
3.
Timer function 40 min.
4. Timer function 60 min.
SETTING THE BASIC VENTILATION
To activate the set-up mode for setting basic ventilation, activate the “On/off light” icon for about 3 seconds. When set-up mode is enabled the “On/off
light” icon will flash.
NOTE: If either the “Timer function 40 min.” or “Timer function 60 min.” buttons are activated within 15 seconds after set-up mode has been activated, the
process is interrupted.
When set-up mode is enabled, adjust the vent as follows:
• Activate the “Timer function 40 min.” icon. Until the valve is fully closed.
• Use the “Timer function 60 min.” icon to adjust the vent until the setting for basic ventilation is reached.
• Deactivate the “On/off light” icon to deactivate the set-up mode (The icon will stop flashing).
• The settings for basic ventilation are now saved
SETTING FORCED VENTILATION
To activate the set-up mode for setting forced ventilation, activate the “Timer function 20 min.” icon for about 3 seconds. When set-up mode is enabled,
the “Timer function 20 min.” icon will flash.
When set-up mode is enabled, adjust the vent as follows:
• Activate the “Timer function 40 min.” icon. Until the valve is fully closed.
• Use the “Timer function 60 min.” icon to adjust the vent until the setting for basic ventilation is reached.
• Deactivate the “Timer function 20 min.” icon to deactivate the set-up mode. (The icon will stop flashing)
• The settings for forced ventilation are now saved.
CONNECTING HUMIDISTAT
It is possible to connect a humidistat to the PCB, so that the valet is opened if the humidity exceeds 70%. The humidistat is disconnected when it leaves
the factory.
NOTE: The valve must be adjusted while the humidistat is switched off.
The humidistat is connected as follows:
ENG
LISH
»
A
D
JU
S
TM
EN
T O
F T
H
E V
A
LV
E
1
2
3
4
Unscrew the four screws holding the cover of
the control box.
Move the jumper, see the wiring diagram on
page 42.
2
Screw the lid of the control box on again.
1
3
Summary of Contents for 5703347519796
Page 2: ......
Page 10: ...THERMEX AIRGRIP M 530265000212022021 10 ELDIAGRAM DANSK ELDIAGRAM ...
Page 18: ...THERMEX AIRGRIP M 530265000212022021 18 ELDIAGRAM NORSK ELDIAGRAM ...
Page 26: ...THERMEX AIRGRIP M 530265000212022021 26 KOPPLINGSSCHEMA SVENSKA KOPPLINGSSCHEMA ...
Page 34: ...THERMEX AIRGRIP M 530265000212022021 34 SÄHKÖKAAVIO SUOMI SÄHKÖKAAVIO ...
Page 42: ...THERMEX AIRGRIP M 530265000212022021 42 WIRING DIAGRAM ENGLISH WIRING DIAGRAM ...