9

Cleaning the Unit

1.  Unplug the POWER CORD from the outlet.
2.  Carefully wipe the exterior of the unit with a soft, damp (not wet) cloth and dry thoroughly with a soft, dry 

cloth. Do not use harsh or abrasive cleaners as these may damage the aesthetic finish of the unit.

3.  Remove particulate that may have gathered in the HOT AIR OUTLET using a vacuum with a brush 

attachment.

Replacing the PCO Cell

After some time the “Replace UV BULB” indicator may appear on your LCD SCREEN. This indicates that 
you need to replace your PCO Cell. You may purchase a replacement PCO Cell through your GreenTech 
Environmental Authorized Distributor. If your distributor is not available, please visit www.GreenTechEnv.
com to contact us regarding ordering a PCO Cell directly.
1.  Remove the FILTER ASSEMBLY by following steps 1 through 3 of “Cleaning the Filter”.
2.  Unplug the old PCO Cell by disengaging the electrical adapter in the lower right hand region of the rear 

of the unit.

3.  Slide the old PCO Cell straight out of the rear of the unit.
4.  Slide the new PCO Cell straight into its place in the rear of the unit.
5.  Connect the new PCO Cell by plugging in the electrical adapter to it’s socket.
6.  Replace the FILTER ASSEMBLY by following steps 7 through 9 of “Cleaning the Filter”.

Electrical

Adapter

PCO

Cell

Summary of Contents for PureHeat Cub

Page 1: ...Cub Owner s Manual 3 4 5 6 7 8 10 11 Introduction Specifications Control Panel Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info Warnings Warranty Information ...

Page 2: ...u through proper operation cleaning the filter and replacing the PCO Cell as necessary Thank you for purchasing ThermaWave Cub by GreenTech Environmental Records Purchase Date ___________________________________________________________________________ Model Number ___________________________________________________________________________ Serial Number _____________________________________________...

Page 3: ...er the Hot Air Outlet Specifications Voltage 120V 60Hz Power up to 1500 watts Heat Output 5000BTU Remote Battery CR2025 Temperature Control Range 60 90 Degrees Fahrenheit Heating Element Infrared Positive Thermal Coefficient PTC Element Air Filter Lifetime Washable Air Purifier Photo Catalytic Oxidation PCO Cell Display LCD Coverage Up to 1000 ft2 Dimensions 11 5 x7 5 x13 HxWxD Weight 14 lbs Certi...

Page 4: ... LCD Display Diagram POWER HEATER QUIET WARMER COOLER PURIFIER TIMER timer Control Quiet Mode Control Purifier Control Heating Up Indicator Temperature Indicator Cooling Down Indicator Purifier Indicator Timer Indicator Quiet Mode Indicator ...

Page 5: ...6 Copyright 2010 GreenTech Environmental All Rights Reserved Unit Front Diagram Unit Rear Diagram POWER HEATER QUIET WARMER COOLER PURIFIER TIMER ...

Page 6: ...er Mode on or off press the PURIFIER CONTROL button Set the desired temperature using the TEMPERATURE CONTROL buttons You may select a temperature from 60 to 90 degrees Fahrenheit Purifier Mode Toggle the Purifier Mode on or off at any time that the unit is turned on by pressing the PURIFIER CONTROL button Timer Function Set the TIMER FUNCTION by pressing the TIMER CONTROL button to activate it Pr...

Page 7: ...E Maintaining The Unit Cleaning the Filter The filter should be cleaned every 30 days or more often if you find that the filter is collecting visible particulate 1 Unplug the POWER CORD from the outlet 2 Remove the FILTER ASSEMBLY SCREW using a screwdriver Place the screw aside where you will not misplace it 3 Allow the FILTER ASSEMBLY to lean away from the rear of the unit until it is free to be ...

Page 8: ...se a replacement PCO Cell through your GreenTech Environmental Authorized Distributor If your distributor is not available please visit www GreenTechEnv com to contact us regarding ordering a PCO Cell directly 1 Remove the FILTER ASSEMBLY by following steps 1 through 3 of Cleaning the Filter 2 Unplug the old PCO Cell by disengaging the electrical adapter in the lower right hand region of the rear ...

Page 9: ...milar attributes 6 Do not insert any foreign objects into the vent as this may cause an electric shock or damage the heater itself 7 Do not change the heater s wiring or design as it will void the warranty and could cause injury 8 Always unplug heater when not in use 9 Turn heater off before removing plug from outlet 10 Do not place cord under any kind of covering such as carpet rugs or similar ar...

Page 10: ...paired or replaced part of unit shall be warranted to the original purchaser only for the length of the unexpired portion of the original warranty For the location of the nearest GreenTech Environmental Authorized Service Center or for other service information please visit us online at www GreenTechEnv com service Before any product is sent for service the customer should contact the GreenTech En...

Reviews: