Page 1: ...OVER 60 YEARS OF STEAM SHOWER INNOVATION Installation Manual For Tutorials and Troubleshooting visit www thermasol com solutions Digital Shower Package ...

Page 2: ...2 2 ThermaTouch Control 7 Inch Screen Installation Manual For Tutorials and Troubleshooting visit www thermasol com solutions TT7X XX OVER 60 YEARS OF STEAM SHOWER INNOVATION ...

Page 3: ...PPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY IF YOU ARE FEELING UNCOMFORTABLE DIZZY FAINT OR STARTING TO FALL ASLEEP IMMEDIATELY EXIT THE STEAM ROOM DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT THERMASOL STEAM BATH GENERATORS ARE NOT DESIGNED TO BE ...

Page 4: ...ing Power Supply Brick Item 03 7142 Materials needed o ThermaTouch control o M12 cable o Silicone o Power Distribution Module PDM o Mud Ring o Ethernet Cable with RJ 45 Connector not supplied o Other materials as required Back of Control REMINDER in order to receive software updates the unit must be plugged into the internet using an Ethernet Cable connected to a Router Router and Ethernet Cable n...

Page 5: ...er location DO NOT pinch nail staple wedge or bind the data cable DO NOT wrap the data cable around steam line or route it in a manner so that the hot steam line could melt the cable Any damage to the control cable will result in the control not working properly Carefully connect the data cable to the PDM and control BEFORE turning power on to the generator or PDM ON Turn Clockwise OFF Turn Counte...

Page 6: ...ALING THE CONTROL TO THE WALL Power on the control and see that it lights up Coat the entire groove on the control back with supplied waterproof silicone to fully seal the control to the wall Completely seal the control to the wall so moisture does not collect behind it Place the control on the wall pressing firmly You may need to tape the control into place until the silicone dries Be careful not...

Page 7: ...LS 110v 110v M12 Cable Audio Cable M12 Cable M8 Cable M12 Cable 6a Connecting ThermaTouch to Generator 6b Connecting ThermaTouch to Serenity Light Sound Rainhead THERMASOL COM I 800 776 0711 7 Digital Shower Package ...

Page 8: ...rmaTouch to Digital Shower 6b Connecting Total Wellness Package THERMASOL COM I 800 776 0711 TTC SLS 110v M12 Cable M12 Cable Audio Cable TTC SLS 110v M12 Cable M12 Cable Audio Cable M8 Cable 8 8 Digital Shower Package ...

Page 9: ...Digital Shower Valve OVER 60 YEARS OF STEAM SHOWER INNOVATION Installation Manual TDS 3000 9 Digital Shower Package ...

Page 10: ...RE USE THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH DO NOT USE THIS PRODUCT WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS AS THIS CAN BE HAZARDOUS TO YOUR HEALTH All products must be installed in accordance with installation instructions provided Failure to do so may invalidate warranty at manufacturer s discretion 2018 ThermaSol Parts enclosed with the Digital Shower Digital Shower 10 9 x 6 93 ...

Page 11: ...al Shower Valve Digital Interface 110V Power 208 240VAC Steam Generator 110V Power Serenity Light and Sound TTC AUDIO OUT TTC INPUT SLS INPUT CONTROL 2 INPUT CONTROL 1 INPUT 24 VDC INPUT STEAM UNIT INPUT ThermaTouch Control Inside Shower To LAN ROUTER PDM THERMASOL COM I 800 776 0711 Digital Shower Package ...

Page 12: ...e of Application IMPORTANT The Digital Shower Valve must be accessible and should not be sealed in the wall TDS 3000 Digital Shower Valve Digital Interface PDM THERMASOL COM I 800 776 0711 Digital Shower Package ...

Page 13: ...lve System Controller 13 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 15V ACCU TLI Hot Fixing Holes Battery Compartment Power Supply Connector Block Cold Inlets Outlets THERMASOL COM I 800 776 0711 Digital Shower Package ...

Page 14: ...14 7 Mark and Drill Holes 235mm 9 25 235mm 9 25 8mm 0 31 THERMASOL COM I 800 776 0711 Digital Shower Package ...

Page 15: ...Valve System Controller 9 Remove Inlet Retaining Bolt 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X THERMASOL COM I 800 776 0711 15 Digital Shower Package ...

Page 16: ... T L I A U X 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 1 Connect hot and cold water supply 2 Insert inlet connectors 3 re insert retaining bolt 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X IMPORTANT Flush the pipework before connection 16 16 THERMASOL COM I 800 776 0711 Digital Shower Package ...

Page 17: ...U X 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 12 Connect Outlet Pipeworks 1 Connect outlet pipeworks 2 Insert outlet connectors 3 re insert retaining bolt IMPORTANT Flush the waterlines prior to connecting to clear any debris 1 2 3 1 3 2 17 THERMASOL COM I 800 776 0711 Digital Shower Package ...

Page 18: ... 2 M O T O R T L I A U X 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X RS232 Port Connect the digital interface to the RS232 port THERMASOL COM I 800 776 0711 Digital Shower Package ...

Page 19: ...19 15 Connect The PDM 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X THERMASOL COM I 800 776 0711 Digital Shower Package ...

Page 20: ... Re fit Cover and Connect 1 5 V A C C U E X T R S 2 3 2 M O T O R T L I A U X IMPORTANT Electrical connection must be installed by a qualified electrician THERMASOL COM I 800 776 0711 Digital Shower Package ...

Page 21: ...pport Department In addition we ll keep you informed about your product and time to time we ll update you about new products and other company announcements Thank you from all of us at ThermaSol and we wish you many relaxing and steamy days ahead We will not sell rent or share your personal information 1958 Steam Way Round Rock TX 78665 21 THERMASOL COM I 800 776 0711 Digital Shower Package ...

Page 22: ...1958 STEAM WAY ROUND ROCK TX 78665 PHONE 800 776 0711 FAX 800 556 5257 WWW THERMASOL COM 81246_NC ...

Reviews: