Thermasol Signature Series Installation Manual Download Page 5

Recessed Control

(shown)

Silicone 

(included)

5

THERMASOL.COM  

I

  800.776.0711

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. 

Signature Series Control Installation Instructions

5

 

Mud Ring Instal Sealing Control

 

For Recessed Controls Only 

(SEMR-XX and SEMR-NTS-XX)

Sealing Control

For Surface Controls Only 

(SEC-XX, SEM-XX, SET-XX, SER-XX, SEC-NTS-XX, 
 SEM-NTS-XX, SET-NTS-XX, SER-NTS-XX)

Step 1: BEFORE TILE - Use the 
supplied mud ring by attaching to 
wall face using a few standard screws. 
Then tile to the edge of the mud ring.

Step 2: Once finished tile is com-
pleted remove mud ring from wall. 
Ensure that the total minimum depth 
is 5/8” so control face sits flush to 
wall. Connect cable so it is not lost 
in wall. Test fit for flushness.

Step 3IMPORTANT: Fully test the control 
system prior to silicone.
 

Once desired fit is achieved coat back of con-
trol face with supplied silicone. Firmly press 
to wall surface and wipe excess silicone from 
around control. Tape into LEVEL position and 
let dry for 24 hours before using steam bath.

Data 

Cable

Step 1: Coat the entire groove on the control back with supplied water-
proof silicone to fully seal the control to the wall. Completely seal the 
control to the wall so moisture does not collect behind it. 

Step 2: Place the control on the wall pressing firmly. 
(You may need to tape the control into place until the silicone dries.) 
Be careful not to harm the wall or control with the tape. 
Let dry for 24 hours before using steam bath.

IMPORTANT: Fully test the control system prior to silicone. 

Surface Mount Control

(shown)

1/2" hole for surface mount

81173_NC 3/16

Summary of Contents for Signature Series

Page 1: ...ELECT STEAM Installation Manual For Tutorials and Troubleshooting visit www thermasol com solutions From top L to R SET XX Traditional SEM XX Modern SEMR XX Modern Recessed SEC XX Contemporary SER XX Regency OVER 55 YEARS OF STEAM SHOWER INNOVATION ...

Page 2: ...HEALTH YOUR SHOWER MAY BE A SLIP AND FALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY IF YOU ARE FEELING UNCOMFORTABLE DIZZY FAINT OR STARTING TO FALL ASLEEP IMMEDIATELY EXIT ...

Page 3: ...le Connection Shower wall Materials needed o Signature Series control o CAN Bus Cable included with generator o Silicone o Other materials as required Tools needed o 1 2 drill for surface mount o Follow pre installation instruction on page 5 for recessed mount controls o Drill motor o Other tools as required Controller Contemporary style shown here Installation instructions warranty static cling w...

Page 4: ...ed to run the cable through electrical conduit DO NOT pinch nail staple wedge or bind the data cable DO NOT wrap the data cable around steam line or route it in a manner so that the hot steam line could melt the cable Any damage to the control cable will result in the control not working properly Carefully connect the data cable to the generator and control BEFORE turning power on to the generator...

Page 5: ...h to wall Connect cable so it is not lost in wall Test fit for flushness Step 3 IMPORTANT Fully test the control system prior to silicone Once desired fit is achieved coat back of con trol face with supplied silicone Firmly press to wall surface and wipe excess silicone from around control Tape into LEVEL position and let dry for 24 hours before using steam bath Data Cable Step 1 Coat the entire g...

Page 6: ...eft and to the right of the Select Return button Press button Increase the temperature by touching the UP symbol until desired temperature is displayed Press Select Return button Reduce the temperature by touching the down symbol until desired temperature is displayed Press Select Return button Setting the timer Press the or button until you reach the time menu Press Select Return button Set the t...

Page 7: ...lustrative purposes only Consult with qualified professional for steam room construction details 7 THERMASOL COM I 800 776 0711 7 Trouble Shooting and Error Codes Visit www thermasol com solutions Click on Troubleshoot then click on Signature Series Control Error Codes 81173_NC 3 16 ...

Page 8: ...1958 STEAM WAY ROUND ROCK TX 78665 PHONE 800 776 0711 SUPPORT THERMASOL COM WWW THERMASOL COM WWW THERMASOL COM SOLUTIONS 81173_NC 3 16 ...