Thermasol F-2 Owner'S/Operator'S Manual Download Page 12

SPARE PARTS 

SAUNA 

HEATERS 

H

C

T105-1,  H

C

T120-1,  H

C

T1

44

-1 

H

C

T105-3,  H

C

T120-3,  H

C

T1

44

-3 

Stone compartment 

Stone  holder 

Base  plate 

Top  part 

Casing side  UR 

Casing  FRONT/REAR 

Electrical  casing 

Electrical  casing R 

Electrical  casing  L 

10 

Radiation shield 

11 

Terminal block  bracket 

12 

Electrical casing cover 

13A  Wireset 240  V  1-phase 

heaters 

138 

Wireset 208  V 3-phase 

heaters 

14 

Wiring diagram 

15 

Rating plate sticker 

16 

Adjusting  leg 

17 

Connection cable 

holder 

18 

Terminal block 

19 

Heating  element  set 

20 

Terminal block sticker 

21 

Lead-in plastic 

grommet 

22 

Floor mounting  plate 

23 

Protective  grille 

24 

Overheating  limiter/ 

sensor  bracket 

25 

Overheating limiter/ 

switch 

26 

Contactor bracket 

27 

4-pole  contactor 

28 

Grounding terminal 

� 

\.!.) 

2

/,1/;4  5 

�6 

HCT105-1 

10  kW 

1, 2, 3, 4, 5, 6 

1640 W/240 

VI 

ZSS-110 

HCT120-1 

12.5  kW 

1, 3, 5 

1640 W/240 

VI 

ZSS-110 

2,4, 6 

2350 W/240 

ZSP-240

HCT144-1         

15  kW 

1, 2, 3, 4, 5, 6 

2350 W/240 

V I 

ZSP-240 

HCT105-3         

10  kW 

1, 2, 3, 4, 5, 6 

1640 W/208 

V I 

ZSS-120 

HCT120-3 

12.5  kW 

1,2,3,4,5,6 

2050 W/208 

V I 

ZSP-250 

HCT

144-3         

15  kW 

1, 2, 3, 4, 5, 6 

2460 W/208 

V I 

ZSP-255 

/4 

o-o 

� 

0

0

0

0

0

.)I 

o

,.... 

0

....,

0

,....

0

...., 

�� 

� 

� 

.. 

� 

8} 

-

.,.,1,11.r"A

� ??\ 

Gt) 

12

81205_NC

Summary of Contents for F-2

Page 1: ...e and guarantee IMPORTANT This manual must be left with owner manager or operator of Sauna after it is used by electrician MODEL HCT105 1 HCT120 1 HCT144 1 CONTROLS F 2T F 2 co M To UL STD 875 c us CERTIFIED TO CAN CSA STD 3159549 E60335 2 53 05 MODEL HCT105 3 HCT120 3 HCT144 3 CONTACTORS FX404 FX503 1 81205_NC ...

Page 2: ...2 81205_NC ...

Page 3: ...e 3 MODEL INPUT MIN HEIGHT FT HCT105 1 10 0 6 5 HCT105 3 HCT120 1 12 5 6 5 HCT120 3 HCT144 1 15 0 6 5 HCT144 3 Table 1 20 1 r w 1 r _ _J W t I a o ez o cor a FLOOR AREA MIN MAX SO FT SQ FT 60 94 78 114 97 146 HEATER MIN CLEARANCE FROM WALL AND FENCE 5 MIN 110 kW 6 MIN 112 5 15 kW 21 2 I WOOD FENCE Figure 4 HEATER MIN CLEARANCE FROM BENCHES 0 0 _ Figure 4A V SAUNA ROOM MIN SPACING FROM ADJACENT SUR...

Page 4: ...es Use copper wire from load center to wall mounted contactor Supply cable must have 5 wires including insulated neutral plus separate ground Use 90 C copper wire from contactor to control and from control to room light Also use 90 C copper wire from contactor to Sauna heater within seal tight flex conduit and connect to junction box at heater with 90 connector Connect to the noted terminals and c...

Page 5: ... wire from breaker to wall mounted contactor Supply cable must have 4 wires including insulated neutral plus separate ground Use 90 C copper wire from contactor to control and from control toroom light Also use 90 C copper wire from contactor to Sauna heater within seal tight flex conduit and connect tojunction box under heater at back with 90 connector Connect to the noted terminals and connect g...

Page 6: ...81205_NC ...

Page 7: ...per breaker to contactor contactor to heater HCT105 3 9 800 27 3 208 HCT120 3 12 300 34 1 208 HCT144 3 14 400 40 0 208 Table 1 2 3 4 5 6 GND L1 L1 L2 L2 A1 A2 3 8 copper 3 8 copper 3 8 copper Overheating limiter Sensor Figure 9 Electrical connections of 240 V 1 phase heaters HCT105 1 HCT120 1 HCT144 1 8 copper 8 copper 8 copper 2 3 4 5 6 GND L1 L2 L3 A1 A2 Overheating limiter Sensor Figure 10 Elec...

Page 8: ...81205_NC ...

Page 9: ... H Door Must open out and should not have a lock Size 2 0 x 6 8 with fir rails and double sealed tempered glass I Flooring concrete ceramic tile or heavyduty Vinyl with walking area of removeable SuperDek J Ventilation should be provided by lower vent close to heater 4 from floor and upper vent on opposite wall if possible 6 from ceiling or as low as 24 from floor Vents should be adjustable and sh...

Page 10: ...concrete ceramic tile or a poured type of flooring When this is provided the Sauna can be easily cleaned and kept in a sanitary condition with little effort A carpet is NOT recommended for a Sauna A carpet becomes a perfect breeding ground for bacteria in the moist conditions of a Sauna and a carpet promotes the spread of foot diseases such as athlete s foot For the same reasons wooden duckboard s...

Page 11: ... HEATER MODEL NUMBER DATE OF PURCHASE ORIGINAL OWNER ADDRESS PURCHASED FROM ELECTRICAL CONTRACTOR MUST SIGN HERE DATE OF ELECTRICAL WIRING HOOKUP THERMASOL 800 776 0711 least 30 minutes before water is poured over the stones only one or two dippers full of water should be poured over the hot stones at one time This guarantee will be void if a shower has been installed in the Sauna room This guaran...

Page 12: ... 18 Terminal block 19 Heating element set 20 Terminal block sticker 21 Lead in plastic grommet 22 Floor mounting plate 23 Protective grille 24 Overheating limiter sensor bracket 25 Overheating limiter switch 26 Contactor bracket 27 4 pole contactor 28 Grounding terminal 1 2 1 4 5 6 HCT105 1 10 kW 1 2 3 4 5 6 1640 W 240 VI ZSS 110 HCT120 1 12 5 kW 1 3 5 1640 W 240 V I ZSS 110 2 4 6 2350 W 240 V ZSP...