Owner' 

sf 

Operator's  Manual 

Sauna heater installation,  wiring, 

operating instructions,  troubleshooting, 

maintenance and  guarantee. 

IMPORTANT!  This manual  must 

be left with owner,  manager,  or 

operator of Sauna after it is used  by 

electrician! 

MODEL 

HCT105-1

HCT120-1

HCT144-1

CONTROLS 

F-2T

F-2

,.,

.... ,

.

�  co�M���

T

� 

UL STD 875 

us 

CERTIFIED TO 

,,.... 

CAN/CSA STD 

3159549 

E60335-2-53-05 

MODEL 

HCT105-3

HCT120-3

HCT144-3

CONTACTORS 

FX404 

FX503 

1

81205_NC

Summary of Contents for F-2

Page 1: ...e and guarantee IMPORTANT This manual must be left with owner manager or operator of Sauna after it is used by electrician MODEL HCT105 1 HCT120 1 HCT144 1 CONTROLS F 2T F 2 co M To UL STD 875 c us CERTIFIED TO CAN CSA STD 3159549 E60335 2 53 05 MODEL HCT105 3 HCT120 3 HCT144 3 CONTACTORS FX404 FX503 1 81205_NC ...

Page 2: ...2 81205_NC ...

Page 3: ...e 3 MODEL INPUT MIN HEIGHT FT HCT105 1 10 0 6 5 HCT105 3 HCT120 1 12 5 6 5 HCT120 3 HCT144 1 15 0 6 5 HCT144 3 Table 1 20 1 r w 1 r _ _J W t I a o ez o cor a FLOOR AREA MIN MAX SO FT SQ FT 60 94 78 114 97 146 HEATER MIN CLEARANCE FROM WALL AND FENCE 5 MIN 110 kW 6 MIN 112 5 15 kW 21 2 I WOOD FENCE Figure 4 HEATER MIN CLEARANCE FROM BENCHES 0 0 _ Figure 4A V SAUNA ROOM MIN SPACING FROM ADJACENT SUR...

Page 4: ...es Use copper wire from load center to wall mounted contactor Supply cable must have 5 wires including insulated neutral plus separate ground Use 90 C copper wire from contactor to control and from control to room light Also use 90 C copper wire from contactor to Sauna heater within seal tight flex conduit and connect to junction box at heater with 90 connector Connect to the noted terminals and c...

Page 5: ... wire from breaker to wall mounted contactor Supply cable must have 4 wires including insulated neutral plus separate ground Use 90 C copper wire from contactor to control and from control toroom light Also use 90 C copper wire from contactor to Sauna heater within seal tight flex conduit and connect tojunction box under heater at back with 90 connector Connect to the noted terminals and connect g...

Page 6: ...81205_NC ...

Page 7: ...per breaker to contactor contactor to heater HCT105 3 9 800 27 3 208 HCT120 3 12 300 34 1 208 HCT144 3 14 400 40 0 208 Table 1 2 3 4 5 6 GND L1 L1 L2 L2 A1 A2 3 8 copper 3 8 copper 3 8 copper Overheating limiter Sensor Figure 9 Electrical connections of 240 V 1 phase heaters HCT105 1 HCT120 1 HCT144 1 8 copper 8 copper 8 copper 2 3 4 5 6 GND L1 L2 L3 A1 A2 Overheating limiter Sensor Figure 10 Elec...

Page 8: ...81205_NC ...

Page 9: ... H Door Must open out and should not have a lock Size 2 0 x 6 8 with fir rails and double sealed tempered glass I Flooring concrete ceramic tile or heavyduty Vinyl with walking area of removeable SuperDek J Ventilation should be provided by lower vent close to heater 4 from floor and upper vent on opposite wall if possible 6 from ceiling or as low as 24 from floor Vents should be adjustable and sh...

Page 10: ...concrete ceramic tile or a poured type of flooring When this is provided the Sauna can be easily cleaned and kept in a sanitary condition with little effort A carpet is NOT recommended for a Sauna A carpet becomes a perfect breeding ground for bacteria in the moist conditions of a Sauna and a carpet promotes the spread of foot diseases such as athlete s foot For the same reasons wooden duckboard s...

Page 11: ... HEATER MODEL NUMBER DATE OF PURCHASE ORIGINAL OWNER ADDRESS PURCHASED FROM ELECTRICAL CONTRACTOR MUST SIGN HERE DATE OF ELECTRICAL WIRING HOOKUP THERMASOL 800 776 0711 least 30 minutes before water is poured over the stones only one or two dippers full of water should be poured over the hot stones at one time This guarantee will be void if a shower has been installed in the Sauna room This guaran...

Page 12: ... 18 Terminal block 19 Heating element set 20 Terminal block sticker 21 Lead in plastic grommet 22 Floor mounting plate 23 Protective grille 24 Overheating limiter sensor bracket 25 Overheating limiter switch 26 Contactor bracket 27 4 pole contactor 28 Grounding terminal 1 2 1 4 5 6 HCT105 1 10 kW 1 2 3 4 5 6 1640 W 240 VI ZSS 110 HCT120 1 12 5 kW 1 3 5 1640 W 240 V I ZSS 110 2 4 6 2350 W 240 V ZSP...