ThermaQ MIDI Installation And Operating Instructions Manual Download Page 6

Maintenance

note: do not attempt to repair this water heater yourself, call a qualified plumber for 
assistance. before maintenance takes place, the power supply needs to be shut off.

the thermaQ Midi does not require any regular maintenance. however, to ensure 
consistent water flow, it is recommended to complete the following.

1.  Periodically remove scale and dirt that may build up at the aerator of the faucet or in  
 

the shower head. 

2.  your water heater includes a Magnesium sacrificial anode as part of the immersion    
 

heater assembly. The anode is present to ensure that your water heater tank does    

 

not corrode, should this device not be serviced. The location of the immersion is as    

 

described above and is accessible from the grey service hatch on the bottom of  

 

the unit.

3.  The anode should be inspected annually and its condition checked, if the anode    
 

is sufficiently corroded it should be replaced to ensure the protection of your water   

 heater.

4.  The pressure relief valve should be inspected annually as well as the expansion  

 

 

vessel, check valve and pressure reducing set if fitted.

Guarantee

your ThermaQ water heater is guaranteed for a period of 12 months from the date of 
purchase. The unit is only guaranteed if the water heater has been installed and maintained 
in accordance with  these instructions. Full guarantee information can be found at: 

thermaQ.co.uk/guarantee.

Trouble-Shooting

Excellence in Hot Water Technology.

10

11

 

ThermaQ Specification Hotline 01924 270847

ProBlems

PossIBle causes

correctIve actIoNs

the pressure release 

valve is constantly 

discharging or 

dripping.

• 

The incoming cold mains 

     pressure is to high.

• 

Please fit pressure reducing set     

     in-line with system 3.

the pressure release 

valve drips or 

discharges whilst the 

unit is heating up.

• 

There is insufficient expansion for 

     your system.

• 

Please fit an expansion vessel or 

     increase the vessel size.

the unit is not 

producing any hot 

water.

• 

The unit is not powered up.

• 

The thermal cut-out has activated.

• 

The element has failed.

• 

The thermostat has failed.

• 

Please check the system has  

     access to power supply.

• 

Reset the cut-out in accordance 

     with this manual.

• 

Please replace the immersion 

     heater.

• 

Please replace the thermostat.

Insufficient amounts 

of hot water 

available.

• 

The heater has been undersized.

• 

The unit has been mounted the 

     wrong way round.

• 

The thermostat has failed.

• 

Please replace the  heater  with 

     one of adequate size.

• 

Please mount the heater 

     ensuring pipes are facing 

     downwards.

• 

Please replace the thermostat.

the unit has begun 

to leak.

• 

Faulty plumbing connection.

• 

Tank gasket has failed.

• 

Please check all joints to the 

     water heater.

• 

Please replace the gasket that 

     attaches between the tank and 

     the immersion heater.

all other faults

• 

Please contact your installer before contacting ThermaQ Limited.

Item

uNIt

QuaNtIty

Electric Water Heater.

Unit

1

Bracket.

Piece

1

Rubber plug and screw.

Piece

1

Operation and Installation instructions.

Copy

1

Cable Clamp and Screw Sets.

Set

1

PackINg 

lIst

Summary of Contents for MIDI

Page 1: ... 9ND t 01924 270847 f 01924 271310 sales ThermaQ co uk www ThermaQ co uk EXCELLENCE IN HOT WATER TECHNOLOGY ThermaQ endeavour to keep the content of this brochure as up to date as possible We reserve the right to make changes to all ThermaQ products and services at anytime To ensure you have the most current information please contact ThermaQ directly Follow us on twitter ThermaQ EXCELLENCE IN HOT...

Page 2: ...duced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance 7 This appliance MUST be permanently connected to the fixed circuit breaker and it must be installed vertical...

Page 3: ...e mains power supply incoming water pressure and the grounding conditions are adequate and the ammeter and wire are at the correct standard required for installation 3 The appliance must be properly grounded due to the dedicated branch circuits of high voltage within the unit Ground wires must be brought to the ground at the circuit breaker panel 4 This appliance MUST be permanently connected to t...

Page 4: ...ersink module should always have the connections on the top of the unit Fig 1 Fig 2 Fixing unit to an external brick wall System 3 Incoming Cold Mains 5 Bar Or Above Additional Equipment Required 2L Portable Expansion Vessel Check Valve Pressure Reducing Valve HEATER Expansion Vessel Check Valve Closest Cold Draw Off Pressure Reducing Set Service Valve Not Supplied Discharge To Drain Pressure Reli...

Page 5: ... isolated the electricity supply Plumbing Your new water heater s connections are 1 2 BSP fittings and these connections are clearly marked on the unit It is important that these two connections are not swapped over The connection from the heater to the system pipework should be made using flexible stainless steel hoses this facilitates the operation of the unit and also makes future maintenance e...

Page 6: ...uble Shooting Excellence in Hot Water Technology 10 11 ThermaQ Specification Hotline 01924 270847 Problems Possible Causes Corrective Actions The pressure release valve is constantly discharging or dripping The incoming cold mains pressure is to high Please fit pressure reducing set in line with system 3 The pressure release valve drips or discharges whilst the unit is heating up There is insuffic...

Reviews: