16
INSTALLATION INSTRUCTIONS
f
f
Install a drain valve at the lowest point of the cold water supply inlet for future maintenance of the tank.
f
f
Install a 700 kPa pressure and temperature relief valve (PTRV).
f
f
Observe the requirements for expansion control valve (ECV) .
In such case, use a 550 kPa valve.
f
f
A pressure reduction valve (PRV) must be fitted and adjusted to a maximum of 500 kPa.
If the ECV is required,
set PRV to a maximum of 420 kPa
conDenSate DraIn
< 889 (35“)
26
_0
3_0
1_
11
27
1
2
3
4
5
6
1
Condensate drain elbow or
2
Drain pan connected to drain
3
T&P valve
4
Cold water connection
5
Hot water connection
6 Condensate spillover
f
f
Install the condensate drain elbow.
f
f
When installing the unit outdoors, the condensate can drain off freely.
f
f
For indoor installation, the condensate can be routed into a floor drain or routed through the wall up to
889 mm (35”) (see diagram above).
f
f
If required, install a condensate pump.
note
To ensure the condensate drains correctly, never kink the hose
poWer Supply
WarnInG electrocutIon
f
f
before any work, isolate the equipment from the power supply at the control panel.
-
Only qualified electricians must carry out the installation in accordance with these instructions.
-
Observe VDE 0100 [or local regulations] and the regulations of your local power supply utility.
-
The appliance is intended to be permanently connected to fixed wiring.
For the connection to the power supply
the fitted supply cord has to be used.
-
The DHW heat pump must be able to be separated from the mains power supply by an additional isolator,
which disconnects all poles with at least 3 mm contact separation.
For this purpose, use contactors, mains iso-
lators, fuses, etc. on site.
-
Terminals are located inside the control panel and become accessible by removing the equipment lid and the
cover of the wiring chamber).
Summary of Contents for TIHP 300
Page 1: ...INSTALLATION INSTRUCTIONS INTEGRATEDHEATPUMP300L FOR MODEL TIHP 300 OPERATION AND ...
Page 2: ...2 INSTALLATION INSTRUCTIONS ...
Page 25: ...INSTALLATION INSTRUCTIONS 25 Notes ...
Page 26: ...26 INSTALLATION INSTRUCTIONS Notes ...
Page 27: ...INSTALLATION INSTRUCTIONS 27 Notes ...
Page 28: ...Works for you www reece com au Thermann 313698 37792 8934 ...