The carton contains:
1. Instruction manual
2. TMT-PH300 Preheater
3. PH-KTC-1 Sensors
4. Power Cord
Important: Keep all shipping materials until satisfactory operation has
been verified.
Operation - Preparation before powering on
1. Remove TMT-PH300 Preheater from its box and place on a suitable work
bench.
2. Attach PH-KTC-1 sensors to the sensor ports. ("6" in control panel
diagram). Verify that the sensors are properly inserted.
3. Connect the AC plug to a suitable AC power outlet. Make sure the power
outlet has grounding. ("8" in control panel diagram)
4. Turn the unit on. ("7" in control panel diagram)
Note: "
SENS ERRX
" will display if external sensor port X is not connected
properly.
Operation - Mode selection
1. The digital display on default shows "
TYPE 0
", press
"▲"
and
"▼"
("3" and
"4" in control panel diagram) to choose between 3 operation modes (TYPE
0, 1, 2)
2. Press the selection button ("2" in control diagram) to confirm selection.
3. If you need to select another mode at this stage, please turn off power and
then turn on power.