80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:
YES
Value
Units
100-240 Volts
10
Amps
47-63
Hz
850
Watts
Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz.
Input AC Current Waveform (ITHD = 6.87%, 50% Load)
I
RMS
PF
A
-12V
3.3V
5V*
5VSB
1.83
0.98
8.7%
20%
Light
207
12.2/0.2
3.3/4.3
5.1/4.3
5.1/0.6
168
81.24%
4.34
0.99
6.9%
50%
Typical
496
12.3/0.4
3.3/10.8
4.9/10.8
5/1.5
415
83.72%
8.93
1.00
5.8%
100%
Full
1024
12.3/0.8
3.2/21.5
4.9/21.7
4.9/3
821
80.16%
Tested by Electric Power Research Institute, Knoxville, TN.
8/13/2007
Efficiency
%
Rated Output Power
Load
(%)
Rated Specifications
Input Voltage
Input Current
I
THD
(%)
Input
Watts
Fraction
of Load
DC Terminal Voltage (V)/ DC Load Current (A)
Output
Watts
12V (cumulative of 12V1, 12V2, etc.)
12.1/10.4
12.1/26.1
12/52.1
Test Date
Input Frequency
338.3
Type
Ecos ID #
Model Number
Serial Number
Year
ATX
NA
2007
Manufacturer
83.72%
81.71%
Thermaltake
W0131RU
Input and Output Power
Input Watts
Output Watts
0
200
400
600
800
1000
1200
20%
50%
100%
Loading (% of Rated Output Power)
P
o
w
e
r
(W
a
tt
s
)
Efficiency of the Power Supply
30%
40%
50%
60%
70%
80%
90%
0%
25%
50%
75%
100%
125%
Loading (% of Rated Output Power)
E
ff
ic
ie
n
c
y
(
%
)
Efficiency %
These tests were conducted as a part of the 80 PLUS program. 80 PLUS is
a computer buy-down program to promote high-efficiency power supplies
(greater than 80% efficiency in the active mode) in desktop computers and
desktop-derived servers.
Input Current and Voltage Waveforms
-200
-150
-100
-50
0
50
100
150
200
0
0.003
0.006
0.009
0.012
0.015
Time (s)
V
o
lt
a
g
e
(
V
)
-15
-10
-5
0
5
10
15
C
u
rr
e
n
t
(A
)
Voltage
Current