37
2.
After the second hour, the indoor fan is fixed at low speed. (Anti-cold wind
function has the priority in heating mode.)
3.
After seven (7) hours of being activated, the air conditioner exit sleep mode and
resume the mode and temperature that it was originally in.
4.
Timer setting is available.
8.4.9 Auto-Restart Function
The indoor unit is equipped with an auto-restart function. In the case of a sudden power loss,
the unit has a built in module that memorizes the mode and temperature settings. When the
power resumes, the unit will automatically restart with the same settings as before the power
outage.
If AC was off before the power outage, and AC is required to start up now, the compressor will
have 1 minute delay when power resumes. Other conditions, the compressor will have 3
minutes delay when restarts.
8.4.10 Refrigerant Leakage Detection
With this new technology, the disp
lay area will show “
EC
” when the outdoor unit detects
refrigerant leakage. This function is only available in cooling mode.
8.4.11 Louver Position Memory Function
When starting the unit again after shutting down, its louver will restore to the angle originally
set by the user, but the precondition is that the angle must be within the allowable range, if it
exceeds, it will memorize the maximum angle of the louver. During operation, if the power fails
or the end user shuts down the unit in the turbo mode, the louver will restore to the default
angle.
8.4.12 Freezing Protection
In heating mode, the set temperature can be set to 46°F (8°C) to prevent things from freezing
when the house is unoccupied for a long time in severe cold weather.
“
” shows on
the
display window of panel while this feature is activated.
8.4.13 Self Clean Function
For heat pump models, after running in cooling or drying mode, if the user press “Self Clean”
button on remote control, firstly, indoor unit runs in fan only mode for a while, then low heat
operation and finally runs in fan only again. This function will automatically clean and dry the
Evaporator and keep the inside of indoor unit dry and prevent breeding of mold for the next
operation. “
” shows on the display window of
panel while this feature is activated.
The Self Clean function will last approximately 16 minutes.
8.4.14 Follow Me
This allows the room temperature sensing to be transferred from the wall unit (evaporator) to
the remote control.
Summary of Contents for 12H47YIMI
Page 10: ...10 1080 mm 226 mm 335 mm 30H48ZIMI 49 57 1259 mm 11 1 282 mm 14 25 362 mm 36H46ZIMI...
Page 19: ...19 Model Voltage V Capacity BTU Type 12H47ZOMI 230 12 000 HEAT PUMP...
Page 56: ...56 P W N U...
Page 57: ...57 N V N W...
Page 82: ...82 7 Then lift the PCB assembly off the unit NOTE All wires are still connected...