APPENDIX
36
Manual 0-2581
APPENDIX II: SEQUENCE OF OPERATION
(BLOCK DIAGRAM)
ACTION
ON/OFF switch
to OFF
RESULT
All indicators off.
Power supply fans off.
ACTION
RUN/SET switch
to RUN.
RESULT
Gas flow stops.
GAS indicator off.
ACTION
Torch moved within
transfer distance of workpiece.
RESULT
Main arc transfer.
Pilot arc off.
ACTION
Torch deactivated (by torch switch
release or by remote device).
RESULT
Main arc stops.
(Power supply enable signal removed.)
Gas flows (15 seconds)
NOTE - If torch is activated during
post-flow, pilot arc will immediately restart.
If torch is within transfer distance (3/8 in) of
workpiece, main arc will transfer.
After post-flow:
Gas solenoid closes, gas flow stops.
GAS indicator off.
ACTION
Open external
disconnect.
RESULT
No power to system.
ACTION
Close external
disconnect switch.
RESULT
Power to system.
ACTION
RUN/SET switch
to SET.
RESULT
Gas solenoid open,
gas flows to set pressure.
GAS indicator on.
ACTION
Torch moved away
from work (while
still activated).
RESULT
Main arc stops.
Pilot arc automatically
restarts.
PILOT ARC
ACTION
ON/OFF switch
to ON.
RESULT
AC indicator blinks for 8
seconds then steady on.
Fans on.
Power circuit ready.
ACTION
Protect eyes and
activate torch
RESULT
Gas flows (2 seconds).
After gas pre-flow:
DC indicator on.
Pilot relay closes.
Pilot arc established
A-00926
Summary of Contents for Pak Master 100XL
Page 2: ......
Page 6: ......
Page 14: ...GENERAL INFORMATION 8...
Page 30: ...OPERATION 24 Manual 0 2581...
Page 36: ...SERVICE 30 Manual 0 2581...
Page 40: ...PARTS LISTS 34 Manual 0 2581...
Page 43: ...Manual 0 2581 37 APPENDIX...
Page 44: ...APPENDIX 38 Manual 0 2581 APPENDIX III SYSTEM SCHEMATIC A 01360...
Page 45: ...Manual 0 2581 39 APPENDIX A 01360 B EC 8055 HAS 11 23 98...
Page 46: ......