Manual 0-4691
3-11
INSTALLATION
3
3.09 Power Supply Connection to Alternate Standoff Control
The Power Supply rear panel includes a knockout to accept wiring between the Automation Interface PC Board and alternate CNC
controls. The Automation Interface PC board includes a terminal strip for connection to alternate CNC controls.
To connect an alternate CNC Control to the Power Supply:
1.
Remove the Power Supply Cover.
2.
Carefully open the lower knockout (below the factory-installed CNC connector) on the Power Supply rear panel.
CPC Connector for
Thermal Dynamics
CNC Controller
Art # A-04178
Knockout for Alternate
CNC Controller
3.
Install a customer-supplied through-hole protector ('Strain Relief') in the lower knockout hole.
4.
Route the wire harness from the alternate CNC Control through the through-hole protector.