8-2-5 Setup Menu
Setup
CW0 CW1
Meaning
OW
PRM Byte
PRM
RV Bytes
Count
0x00 0x05 Read camera
temperature
0x00
0
None
2
0x00
0x11
Save settings
0x01
0
None
1
0x00
0x12
Recover
0x02
0
None
1
0x00
0x15 Automatic NUC
switch (savable)
0x01
1
0x00: Auto-
correction off
0x01: Auto-
correction on
(default open)
1
Automatic correction
of on-off status
reading
0x00
0
None
1
0x00
0x16 Read FPA
temperature
0x01
1
0x00: Shutter
correction (default)
0x01: Background
correction
1
0x00
0x17
Set the time interval
for automatic NUC
(savable)
0x01
1
Time range: 0 -
255
Unit: second
1
Automatic correction
of time interval reads
0x00
0
None
1
0x00
0x18 Set automatic NUC
temperature interval
(savable)
0x01
1
Temperature
range: 0 - 255
Unit: Celsius
1
Automatic correction
of temperature
interval reads
0x00
0
None
1
PLEASE READ AND UNDERSTAND THE TABLES BEFORE SWITCHING THE UNIT ON.