Input Power
Each unit incorporates an INRUSH circuit. When the MAIN CIRCUIT SWITCH is turned on, the inrush circuit provides
pre-charging for the input capacitors. A relay in the Power Control Assembly (PCA) will turn on after the input capacitors
have charged to operating voltage (after approximately 5 seconds)
NOTE
Damage to the PCA could occur if 253 VAC or higher is applied to the Primary Power Cable.
Model
Primary Supply Lead
Size (Factory Fitted)
Minimum Primary
Current Circuit Size
(Vin/Amps)
Current & Duty Cycle
LIFT TIG/ HF TIG
(GTAW)
STICK (SMAW)
Thermal Arc
161 STL
12 AWG (3.3mm²)
115V/30A
-
100A @ 45%
115V/30A
150A @ 35%
-
208-230V/25A
-
160A @ 30%
208-230V/15A
160A @ 30%
-
Thermal Arc
201 TS
12 AWG (3.3mm²)
115V/30A
-
100A @ 45%
115V/30A
150A @ 35%
-
208-230V/25A
-
200A @ 20%
208-230V/25A
200A @ 25%
-
Table 3-2: Primary Circuit Sizes to Achieve Maximum Current
Summary of Contents for 161 STL
Page 6: ......
Page 16: ...THERMAL ARC 161STL 201ts INTRODUCTION Introduction 2 2 Manual 0 5148 Notes...
Page 42: ...THERMAL ARC 161Stl 201ts THEORY OF OPERATION Theory of Operation 5 2 Manual 0 5148 Notes...
Page 72: ...THERMAL ARC 161Stl 201ts disassembly procedure Disassembly Procedure 7 14 Manual 0 5148 Notes...
Page 84: ...THERMAL ARC 161Stl 201ts ASSEMBLY PROCEDURES Assembly Procedures 8 12 Manual 0 5148 Notes...
Page 90: ...THERMAL ARC 161Stl 201TS replacement parts Replacement Parts 9 6 Manual 0 5148 Notes...
Page 92: ...THERMAL ARC 161Stl 201TS accessories Accessories 10 2 Manual 0 5148 Notes...
Page 95: ......