background image

CONTROL PCB REPLACEMENT INSTRUCTIONS

0-5248 Rev AB 

May 16, 2012

© 2012 by Thermadyne Industries

Kit Componants

The following components are included in this kit.

•  Control Panel PCB Assembly
•  Anti Static Strap
•  Mounting Screws (4)
•  Instructions

Control PCB Replacement 

NOTE

This process is the same for the Fabricator and the Transmig units. Transmig is shown in these in-

structions.

1.  Disconnect power from the power supply
2.  Locate the anti static strap in this kit and follow instructions for proper use and fit it to your body.
3. 

Remove four (4) Control Panel screws (#1).

#1

Art # A-1

Figure 1: Front Panel Screw Removal (Transmig shown)

Thermadyne Holdings Corporation

Suite 300, 16052 Swingley Ridge Road

St. Louis, MO 63017, USA

Telephone: 1-800-426-1888  • Fax:  1-800-535-0557

Email:  [email protected]

www.thermalarc.com

Manual 0-5248

Control PCB Replacement and 

Part Numbers for 

Fabricator 252i US W7005381
Fabricator 252i EU W7005388

Transmig 250i W7005336

Assembly Instructions

Reviews: