Figure 54: Solenoid
—XLO Valve—Potentiometer Assembly
10. Remove the white plastic side connector from the potentiometer
by pressing on the connector’s tab. (see Figure 55).
Figure 55: Side Connector Tab
11. Replace the XLO valve if needed.
12. Detach the XLO valve from the potentiometer by using a small
flat-blade screwdriver to gently remove the XLO valve from the
potentiometer standoffs. Then slide the potentiometer off the valve
stem (see Figure 56).
Figure 56: Removing the XLO Valve from the Potentiometer
Gas Leaks
Carefully check for gas leaks at each gas component that was
removed, replaced, or otherwise serviced using a gas leak detector or
bubble test.
Side