8. Now remove the manifold support brackets by removing and
retaining the following screws with a T-20 driver:
■ The two screws holding the manifold support bracket onto the
chassis base near the regulator (see Figure 46)
■ The two screws from each bezel of the two inner knobs
(see Figure 44 and Figure 45) to detach the manifold support
brackets from the back of the control panel (see Figure 47)
9. After removing all brackets, gently lift the manifold out, being
careful of the wires and harnesses and other components.
Gas Leaks
Carefully check for gas leaks at each gas component that was
removed, replaced, or otherwise serviced using a gas leak detector or
bubble test.
Figure 45: Manifold Support Bracket Screws on Bezel
Figure 46: Manifold Support Bracket on Chassis Base
Figure 47: Manifold Support Bracket on Back of Control Panel