
NATURAL GAS REQUIREMENTS -
Inlet Connection:
1/2" NP with 3/8" NPT reducer adapter.
Supply Pressure:
6" to 14" W.C.
Manifold Pressure:
4" W.C.
GAS CONSUMPTION
The total gas consumption of the Thermador Char Glo
®
barbecues with all burners on "HI" is as
follows:
CGB30RFZLP
=
52,000
BTU/Hr
CGB36FZLP
=
77,000
BTU/Hr
CGB48FZLP
=
109,000
BTU/Hr
CGB48FSZLP
=
107,000
BTU/Hr
SECTION 2: GAS REQUIREMENTS
IMPORTANT: Un robinet manuel d'isolement doit étre installé à l’extérieur de l’appareil, dans
un emplacement accessible avec l’unité installée dans la module. Assurez-vous que le robinet est
fermé avant de brancher l’appareil.
▲
!
▲
!
IMPORTANT: A manual gas shut off valve must be installed external to the appliance, in
a location accessible with the unit installed in the enclosure. Make sure the valve is turned
off prior to connecting the appliance.
Page 2
PROPANE HOOK-UP
Tank Gas Regulator
LP Gas Tank
Gas Hose
Figure 1
PROPANE GAS REQUIREMENTS -
Inlet Connection:
1/2" NP with 3/8" NPT reducer adapter.
Supply Pressure:
11" to 14" W.C.
Manifold Pressure:
10" W.C.
Summary of Contents for Char Glo CGB30CZLP
Page 11: ...NOTES...