 THERMADOR  HOOD WARRANTY

FULL ONE YEAR WARRANTY

Covers one year from date of installation, or date of occupancy on a new, or previously unoccupied dwelling.
Save your dated receipt or other evidence of installation/ occupancy date.

Thermador Will  Pay  For:

All repair labor and replacement parts found to be defective due to materials and workmanship.

Service must be provided by a Factory Authorized Service Agency, during normal working hours. For a
Service Agency nearest you, please call 800/735-4328.

Thermador Will Not Pay For:

I.

Service by an unauthorized agency Damage or repairs due to service by an unauthorized agency or the
use of unauthorized parts.

2.

Service visits to:

Teach you how to use the appliance.

Correct defects or repairs due to improper installation. You are responsible for providing electrical
wiring and other connecting facilities.

Reset circuit breakers or replace home fuses.

Damage caused from accident, alteration, misuse, abuse, improper installation or installation not in
accordance with local electrical codes or plumbing codes, or improper storage of the appliance.

Service labor during limited warranty period.

Travel fees and associated charges incurred when the product is installed in a location with limited or
restricted access. (i.e., airplane flights, ferry charges, isolated geographic regions).

Repairs due to other than normal home use.

This warranty applies to appliances used in residential applications; it does not cover their use in commercial
installations.

The warranty is for products purchased and retained in the 50 states of the U. S. A., the District of Columbia
and Canada. Should the appliance be sold by the original purchaser during the warranty period, the new
owner continues to be protected until the expiration date of the original purchaser’s warranty period. Products
for use in Canada must be purchased through the Canadian distribution channel to ensure regulatory compliance
and warranty coverage

This warranty gives you specific legal rights. You may also have other rights which vary from state to state.

HOW TO OBTAIN SERVICE

Contact the Factory Authorized Service Agent in your area.

Contact the Dealership where you purchased the appliance.

Call the Thermador Customer Support Call Center at 800-735-4328.

Write us to at:Thermador 5551 McFadden Avenue, Huntington Beach CA, 92649.

PAGE 14

Summary of Contents for An American Icon PH30ZS

Page 1: ...mps 1 Infra Red Heat Lamps 2 Filters 3 Step Down Transformer 4 Main Relay Board 5 Input Board 6 Heat Sensor 7 Control Panel 8 Cleaning Instructions 9 Disassembly 10 Stainless Steel Parts 11 Transforme...

Page 2: ...Wiring Diagram...

Page 3: ...equivalent tool pry loose the lens cover as shown in Figure 3 Remove the damaged light and replace with a new 12 Volt 20 Watt maximum halogen light made for a G 4 base Follow package directions and d...

Page 4: ...d produces the same amount of effective heat with lower energy consumption These lamps may not be readily available at local retail outlets The PAR 40 250W heat lamp is readily available at local reta...

Page 5: ...m and are long lasting To RemoveThe Metal Grease Filters Turn the fan and lights off Allow filters to cool before removal In the following order remove the baffle filters trims and grease troughs To r...

Page 6: ...ep DownTransformer The step down transformer is a multiple tap 120 v a c step down transformer one tap outputs 12 v a c for regular lights and the other tap outputs 9 6 v a c when the dim light is sel...

Page 7: ...oard The main relay board is a microproccessor based printed circuit board The relay board has specific relays to activate the components in the hood The relay board reacts to input and commands from...

Page 8: ...e input board serves as a selector switch the mode is selected on the input board buttons The input board sends the commands to the relay board The relay board and the input board communicate through...

Page 9: ...corresponding LED will blink 2 If the ventilator is on at any speed the corresponding LED will blink No speed change will occur While the sensor is activated due to excessive heat 1 The ventilator spe...

Page 10: ...High DELAY SHUT OFF BUTTON Press to turn fan on high for 10 minutes If the ventilator is off when the delay button is pressed the ventilator will turn on to the high speed setting for 10 minutes At th...

Page 11: ...dishwasher To Clean Hood Surface For general care wipe the outside of the stainless steel with sudsy water or household cleaners such as Fantastic or Formula 409 Rinse well and dry with clean soft cl...

Page 12: ...ual PAGE 10 The halogen lights and infra red lights are mounted on the light panel To drop light panel and gain access to components 1 Remove 3 screws as illus trated and drop the light panel Disassem...

Page 13: ...11 Stainless Steel Parts The stainless st5eel parts illustrated below are field replaceable Inside Panel Spacer Light Panel Grease Trough Grease Trough Top Trim Filters Spacer Inside Panel Replaceabl...

Page 14: ...t panel 2 Remove 4 screws that attach the transformer panel to the sides of the hood see illustration The step down transformer electronic control and wire harness are mounted on the transformer panel...

Page 15: ...t board is mounted on the inside of the hood To remove the input board 1 Remove light panel 2 Remove 4 number 9 hex head nuts that attach the input board to the hood see illustration Input Board Remov...