EX-TRAFIRE
®
40SD
Operator Manual, Revision T-15
2-12
Open circuit voltage (U
0
)
480 VDC
Output characteristic*
*
Curve is defined as the output voltage versus output current
Drooping
Input voltage (U
1
)
*PFC
100 - 130 VAC (CE)
220 - 240 VAC (CE/C-TICK)
Rated output current (I
2
)
10–30 A
10–40 A
standard rated output voltage (U
2
)
at U
1
= 220 - 240 VAC
140 VDC
X
40%
60%
100%
U
2
120 V
140 V
140 V
standard rated output voltage (U
2
)
at U
1
= 100 - 130 VAC
X
35%
60%
100%
U
2
92 V
90�4 V
88�4 V
Cutting current at 35%/60%/100% duty cycle
100 - 130 VAC (CE)
30/26/21 A
Cutting current at 40%/60%/100% duty cycle
220 - 240 VAC (CE/C-TICK)
40/30/25 A
Maximum input power
100 - 130 VAC (CE)
3�45 kVA
220 - 240 VAC (CE/C-TICK)
5�98 kVA
Duty cycle (X*) at 40º C at rated conditions (U
1
, I
1
, U
2
, I
2
)
*X=Ton/Tbase,
Ton = time, minutes
Tbase =10 minutes
U
1rms
X
100 - 130 VAC (CE)
35%
220 - 240 VAC (CE/C-TICK)
40%
Operating temperature
−10º – +40º C
Rated AC phases (PH) and line frequency (Hz)
Model CE
PH
Hz
1
50-60
Rated input voltage (U
1
), rated input current (I
1
) and
effective input current (I
1eff
*) at rated output voltage
(U
2
) and rated output current (I
2
) - for cutting only�
* I
1eff
= (I
1
) √X
used to determine rating of power cord�
eff = effective
rms = root mean square
U
1rms
I
1rms
I
1eff
100 - 130 VAC (CE)
28�8*A
17*A
220 - 240 VAC (CE/C-TICK)
26*A
16�4*A
This equipment conforms to IEC 60974-1, IEC 60974-10
Isolation class
F
IP Code – Degree of protection provided by enclosure
IP23S*
IP – “International Protection”
2 – No ingress foreign objects ≥ 12�5 mm
3 – No harmful ingress spraying water�
S – fan stationary during water test�
*
WARNING: ! DO NOT OPERATE IN RAIN !
Toppling, tilting ( with or without Wheel kit)
Up to 15º incline
Gas type
Air
Nitrogen
Gas quality specification
Recommended Air quality:
ISO 8573-1 Class 1�2�2�
Purity ≥ 99�99%
Air max� particle size:
0�1 microns, class 1
ref� to ISO 8573
Air max� oil: 0�1 mg / m3,
class 2 ref�: ISO 8573
Air max� dewpoint: +3° C,
class 4 ref� to ISO 8573
Gas quality
Clean, moisture-free, without oil
Gas input pressure and flow
10 bar/145 psi 120 l/min
Dimensions ( l x h x w ) (mm)
469�9 x 228�6 x 177
Weight (kg)
11�8
Specifications: plasma arc power supply
* PFC
- power factor control automatically detects input voltage and adjusts output current�
Summary of Contents for EX-TRAFIRE 40SD
Page 10: ...EX TRAFIRE 40SD Operator Manual Revision T 15 10 Blank page...
Page 65: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 65 Notes...
Page 66: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 66 Notes...
Page 67: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 67 Notes...
Page 68: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 68 Notes...
Page 70: ...EX TRAFIRE 40SD Operator Manual Revision T 15 12 70 Revision history...