Therma-Stor Santa Fe HC Quick Manual Download Page 8

Santa Fe HC Dehumidifier Limited Warranty

8

Santa Fe HC Owners Manual

WARRANTOR:

Therma-Stor LLC
PO Box 8050
Madison, WI 53708

Telephone: 1-800-533-7533

WHO IS COVERED:

This warranty extends only 

to the original residential end-user of the SANTA
FE HC dehumidifier, and may not be assigned 
or transferred.

FIRST YEAR WARRANTY:

Therma-Stor LLC 

warrants that, for one (1) year the SANTA FE HC
dehumidifier will operate free from any defects 
in materials and workmanship, or Therma-Stor 
LLC will, at its option, repair or replace the 
defective part(s), free of any charge.

SECOND THROUGH FIFTH YEAR WARRANTY:

Therma-Stor Products further warrants that for a
period of five (5) years, the condenser, evaporator,
and compressor of the SANTA FE HC dehumidifier
will operate free of any defects in material or 
workmanship, or Therma-Stor LLC, at its option,
will repair or replace the defective part(s), 
provided that all labor and transportation charges
for the part(s) shall be borne by the end-user. 

END-USER RESPONSIBILITIES: 

Warranty service

must be performed by a Servicer authorized 
by Therma-Stor LLC. If the End-user is unable 
to locate or obtain warranty service from an
authorized Servicer, he should call Therma-Stor
LLC at the above number and ask for the 
Therma-Stor  LLC Service Department., which 
will then arrange for covered warranty service.
Warranty service will be performed during normal
working hours.

The End-user must present proof of purchase
(lease) upon request, by use of the warranty 
card or other reasonable and reliable means. 
The end-user is responsible for normal care. This
warranty only applies to residential applications,

and does not cover any defect, malfunction, etc.
resulting from misuse, abuse, lack of normal care,
corrosion, freezing, tampering, modification, 
unauthorized or improper repair or installation,
accident, acts of nature or any other cause 
beyond Therma-Stor LLCs reasonable control.

LIMITATIONS AND EXCLUSIONS:

If any SANTA FE

HC Dehumidifier part is repaired or replaced, the
new part shall be warranted for only the remainder
of the original warranty period applicable thereto
(but all warranty periods will be extended by the
period of time, if any, that the SANTA FE HC
Dehumidifier is out of service while awaiting 
covered warranty service).

UPON THE EXPIRATION OF THE WRITTEN 
WARRANTY APPLICABLE TO THE SANTA FE HC
DEHUMIDIFIER OR ANY PART THEREOF, ALL
OTHER WARRANTIES IMPLIED BY LAW, INCLUDING
MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE, SHALL ALSO EXPIRE. 
ALL WARRANTIES MADE BY THERMA-STOR LLC
ARE SET FORTH HEREIN, AND NO CLAIM MAY 
BE MADE AGAINST THERMA-STOR PRODUCTS
BASED ON ANY ORAL WARRANTY. IN NO EVENT
SHALL THERMA-STOR PRODUCTS, IN CONNECTION
WITH THE SALE, INSTALLATION, USE, REPAIR OR
REPLACEMENT OF ANY SANTA FE HC DEHUMIDIFIER
OR PART THEREOF BE LIABLE UNDER ANY LEGAL
THEORY FOR ANY SPECIAL, INDIRECT OR 
CONSEQUENTIAL DAMAGES INCLUDING WITHOUT
LIMITATION WATER DAMAGE ( THE END-USER
SHOULD TAKE PRECAUTIONS AGAINST SAME),
LOST PROFITS, DELAY, OR LOSS OF USE OR 
DAMAGE TO ANY REAL OR PERSONAL PROPERTY.

Some states do not allow limitations on how 
long an implied warranty lasts, and some do 
not allow the exclusion or limitation of incidental
or consequential damages, so one or both of
these limitation may not apply to you.

LEGAL RIGHTS:

This warranty gives you specific

legal rights, and you may also have other rights
which vary from state to state.

Summary of Contents for Santa Fe HC

Page 1: ...tion and air filtration True Performance Off the shelf appliance grade dehumidifiers rate their dehumidification capacities at 80 F 60 relative humidity RH The performance of these devices drops signi...

Page 2: ...ed to be installed indoors only 1 Intended Application for Santa Fe HC For the ideal installation draw air from the central part of the home and return it to isolated areas of the home like the bedroo...

Page 3: ...section 5 for attaching duct collars ducting 4 1C In A Remote Area Duct Inlet Outlet Fig 6 It is often desirable especially in recreational rooms and finished areas to install the Santa Fe HC in an a...

Page 4: ...wiring the control 4 2 Remote Humidity Controls All remote humidity controls should be mounted in a central area of the the space to be dehumidified where it can accurately sense the humidity of the...

Page 5: ...duct ends must not excessively restrict air flow Isolated Areas Effective dehumidification may require that ducting be branched to isolated stagnant areas Use 6 diameter branch ducting to each of two...

Page 6: ...ensed by giving up its heat to the air that is about to be discharged from the unit The refrigerant liquid then passes through a filter drier and capillary tubing which cause the refrigerant pressure...

Page 7: ...has melted the evaporator temperature will rise and the thermostat will restart the compressor 9 Service Parts List PART NO DESCRIPTION 4021395 Coil Evaporator 4021396 Coil Condenser 4021470 Thermost...

Page 8: ...plies to residential applications and does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repai...

Page 9: ...Santa Fe HC Owners Manual 9...

Page 10: ...produced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2004 Therma Stor LLC All rights reserved PO Box 8...

Reviews: