SANTA FE COMPACT2 INSTALLER'S AND OWNER'S MANUAL

3

Santa Fe Compact2 Installer’s & Owner’s Manual

3. Specifications

Part Number:

 4033600

Blower:

 

150 CFM @ 0.0" WG

Power:

 

580 watts @ 80°F and 60% RH

Supply Voltage:

  115 volt – 1 phase - 60 Hz

Current Draw:

 

5.1 Amps

Energy Factor: 

  2.4 L/kWh

Operating Temp.:

  49°F Min., 95°F Max.

Sized for: 

Up to 1800 Sq. Ft. - Typical

Minimum Performance at 80°F and 60% RH

Water Removal: 

70 Pints/Day

Efficiency: 

5.0 Pints/kWh

Air Filter:

 

MERV-8 

Efficiency: 

 Standard 65% Efficient,  ASHRAE Dust Spot Test

Size: 

9" x 11" x 1"

Power Cord:

 

9', – 110-120 VAC, Ground

Drain Connection:

  3/4" Threaded MPT

Drain Hose:

 

 5-8" ID x 8'

Santa Fe Dimensions

 

Unit

 

Shipping

Width: 

12" 

15"

Height: 

12" 

17"

Length: 

21"  

25"

Weight: 

55 lbs 

65 lbs

4. Unit Assembly

4.1 Installing Feet

Included with your Santa Fe Compact2 are four leveling feet. 
It is important to level the unit for proper draining. Do not 
install the feet if you are using the optional hang kit.

Adjusting Leveling Feet 

1.  Lay down a protective pad (pillow, blanket, etc.).
2.   Carefully turn unit onto side.
3.  Install leveling feet and adjust to the desired position.
4.  Carefully bring unit to upright position.
5.   Repeat steps 1-4 until unit is capable of proper drainage 

as described in section 5.2.3 of this manual.

6.   Wait a minimum of 10 minutes before operating. 

 CAUTION!

Note: Operating the unit immediately after bringing it to an 
upright position can possibly damage the compressor. A 
minimum of 10 minutes is needed to allow the compressor 
oil to return to it’s reservoir for lubrication.

4.2 Drain Hose

Install the threaded drain hose fitting into the lower right hand 
side, on the front of the machine. Place drain hose end on drain 
port until fully seated. Refer to Section 5.2.3 regarding proper 
drainage.

5. Installation 

5.1 Safety Precautions

•  Do not install the Santa Fe Compact2 with the intake or 

exhaust of the unit within 1' of a wall or other obstruction.

•  Do not place the unit where curtains or debris can be drawn 

onto the intake and restrict airflow. 

•  Do not operate in standing water or place the unit near open 

water.

5.2 Location

The Santa Fe Compact2 can be installed in a variety of locations 
to meet the dehumidification needs, but should be installed 
directly in the area to be dehumidified. Other considerations 
include:
1.   Providing access to a 115 VAC power outlet (9' power cord is 

provided).

2.   Locating near a suitable drain (8' drain hose included).
3.   The unit is designed to operate while level. If the unit is 

placed on an unlevel surface, refer to section 4.1. Failure to 
level the unit may result in leakage or improper drainage.

4.   The unit should be hung from the floor joists if there is  

any possibility of flooding. A flooded unit is not covered  
by warranty.

 WARNING!

5.3 Electrical Requirements

The Santa Fe Compact2 plugs into a common grounded outlet 
on a 110-120 VAC  15-Amp circuit. While operating, it draws 
5.1 amps @ 80°F, 60% RH and 4.5 amps @ 70°F, 50% RH. 
Use of a ground fault circuit interrupter (GFCI) protected circuit 
is recommended. The unit should not be used in areas prone to 
flooding.

5.4 Condensate (Water) Removal

The Santa Fe Compact2 drains via gravity, therefore, it does not 
have the ability to push condensate (water) upwards. The drain 
hose must run down towards the drain location. Condensate 
can be drained by using the 5/8” clear vinyl hose and the 3/4” 
threaded adapter provided. Ensure the threaded adapter is 
threaded in tightly.

 CAUTION!

The Santa Fe Compact2 requires a drain trap. Creating a drain 
trap allows a small amount of water to build up in the trap area 
of the clear hose. This prevents air from back flowing through 
the hose and into the dehumidifier; essentially causing the unit 
to backflow water out of the corners of the machine. Position 
the trap in the hose approximately 8"-10” from the dehumidi-
fier and make sure the highest point of the trap is still at least 
2”below the black drain port adapter on the dehumidifier. If the 
highest point of the trap is above the drain port, water will back 

Summary of Contents for Santa Fe Compact

Page 1: ...age 4201 Lien Rd Madison WI 53704 TOLL FREE 1 800 533 7533 www Santa Fe Products com Designed For Superior Basement and Crawlspace Dehumidification P N 4033600 Serial No ________________________ Insta...

Page 2: ...do not have access to the equipment Do not allow children to play with or near the unit or in its air flow The unit is designed to be installed indoors only No user serviceable components Contact inst...

Page 3: ...n Do not place the unit where curtains or debris can be drawn onto the intake and restrict airflow Do not operate in standing water or place the unit near open water 5 2 Location The Santa Fe Compact2...

Page 4: ...fier run time To turn unit on turn the humidity dial clockwise to the recommended NORMAL position and set fan control to FAN AUTO To turn the unit off turn the humidity dial counter clockwise to the O...

Page 5: ...ondenser coil The refrigerant is cooled and condensed by giving up its heat to the air that is discharged from the dehumidifier The refrigerant liquid then passes through capillary tubing which cause...

Page 6: ...nal overload and a run capacitor but no start capacitor or relay CAUTION CAUTION ELECTRICAL SHOCK HAZARD Electrical power must be present to perform some tests These tests should be performed by a qua...

Page 7: ...s to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibilities As a further con...

Page 8: ...1 800 533 7533 www santa fe products com...

Reviews: