background image

Note: Before attaching pump assembly, ensure that the dehumidifier has either the 
casters or leveling legs installed in it. These will be needed for additional height. The 
mounting bracket is not to be used as a support bracket for the dehumidifier.

Condensate Pump Installation

Step 1.

 Lay the unit on it's side. Make sure the filter door 

is facing upward. Note the locations of the four leveling feet 
and the hose adaptor.

Step 2.

 Partially screw in the leveling feet at the four locations.

Step 3.

 Turn unit upright and install short end of 

hose connector on drain port.

Step 4. 

 

Remove middle top cover screw located on the drain 

port side. Do not discard this screw. It will be used to attach the 
mounting bracket. 

For small usage:

P.O. Box 8680 Madison, WI 53708 

 TOLL-FREE 1-800-533-7533 

 www.thermastor.com 

 [email protected]

TS-408•10/07