SYSTEM REQUIREMENTS
Condensate Water Removal
Condensate drains by gravity via the drain port. Use 3/4” male NPT PVC pipe. Route drain pipe to drain. Install a trap if
possible. Take care when installing drain pipe to drain port. Use an adjustable wrench to secure the drain port. An optional
condensate pump kit may be installed if a lift is required to dispose of the condensate. The condensate pump kit can be ordered
directly from the factory. See the optional parts list for information on the kit.
When installing the drain hose make sure the feet are extended such that the dehumidifier is 2 1/2” off the ground. Then coil
the drain hose under itself or position a spacer to lift the hose 1” off the ground after the hose has touched the ground. This
procedure will create a trap that ensures your unit drains correctly. See the diagram below for further visual clarification.
Hanging Installation Diagram
Ducting
Supply Duct Kit (P/N 4028607)
A factory designed supply duct kit can be purchased to accept 10” ducting to both outlets of the Quest Dual.
Return Duct Kit (P/N 4028610)
A factory designed return duct kit can be purchased to accept 12” ducting.
To order, contact your dealer or visit www.QuestHydro.com.
B
A
B
A
Optional Control
(See Section 5)
Bottom view of
unit and bracket
Bracket (4036668)
note: plumb condensate
water to drain or
reclamation reservoir
P-trap
(see section 4.5 for more info)
B