Ultra-Aire 120V Installation Instructions
70°F and 60% RH
90 pints/day
6.0 Pints/kWh
Shipping
24”
49”
21”
138 lbs.
6" Fresh Air Intake (Optional)
10" Return Air Duct
8" Supply Air Duct #1
Front View
8" Supply Air Duct #2 (Optional)
8" Duct Cover (Optional)
ATTACHING DUCT COLLARS
Before installing the damper and duct collars listed below, apply the corresponding foam tape included for each.
Fresh Air Ventilation Duct
Fresh air ventilation is optional. A 6
"
diameter damper is included with the unit and can be attached to the top
using the corresponding foam tape provided. The 6" damper should be closed if fresh air is not desired. If setting
up the unit to provide fresh air ventilation, see page 17.
Return Air Inlet
A 10
"
diameter duct collar is included with the unit and can be attached to the top with the corresponding
foam tape provided.
Supply Air Outlet #1
An 8
"
diameter duct collar is included with the unit and can be attached to the side using the corresponding
foam tape provided.
Supply Air Outlet #2
An optional 8
"
diameter duct collar is included with the unit and can be attached to the other side with the
corresponding foam tape provided.
Supply Air Duct Cover
An optional 8” diameter duct cover (attached) can be used to block one of the supply air outlets if not being used.
Side View
Air Flow Path